R) Miscellaneous 2
Flash
Code
Error
Error message
TopCon (Long)
Description
Possible Cause
Counteraction
26-1
R0
Output Power Q1
too high
Output power exceeds the set level
during a particular delay time.
Controller overshooting caused by
set value steps.
Decrease steps of set value ramp.
Adapt controller parameters to the load.
26-1
R0
Ouptut Power Q1
too high
Output power exceeds the set level
during a particular delay time.
Controller overshooting
Decrease controller parameters
26-1
R0
Ouptut Power Q1
too high
Output power exceeds the set level
during a particular delay time.
Cf. "21) Overcurrent Isek" and
"30) Overvoltage"
Cf. "21) Overcurrent Isek" and
"30) Overvoltage"
26-2
R1
Output Power Q4
too high
Output power in sink operation (Q4)
exceeds the set level during a pa-
ricular time. Cf. R0)
Cf. "R0) Output Power Q1 too
high"
Cf. "R0) Output Power Q1 too high"
26-3
R2
High resolution of
system reference
values not support-
ed
The system does not support the
option high resolution of system
reference values.
Master or Slave(s) in system do
not support the option high resolu-
tion of system reference values.
Contact customer support
26-4
R3
Earth fault
The value of insulation resistance
between earth and the DC ouptut
bars fall below the set level.
Earth fault detected.
The value of insulation resistance
between earth and DC system is
too low.
Check for earth fault.
Check the cable insulation.
Check the value of insulation resistance between
earth and DC system.
26-5
R4
Output Capaci-
tance is not
switched on yet
(wait time not up or
voltage unstable)
Option Switchable Output Capaci-
tance is enabled and the device was
tried to switch on but the Switchable
Output Capacitance has not
switched on yet.
Switchable Output Capacitance
switching on is only allowed after
output voltage is stable for a spec-
ified time.
Make sure output voltage is stable. Wait (normally
1 minute) and try again.
26-6
R5
DC Discharge Unit
power too high
Power on DC Discharge Unit ex-
ceeds specified limit
A battery is connected to the out-
put.
The connected load violate the
specified limits.
Check if no battery is connected to the ouput.
Check if the connected load does not violate the
specified limits.
26-7
R6
DC Discharge Unit
energy too high
Energy on DC Discharge Unit ex-
ceeds specified limit
A battery is connected to the out-
put.
The connected load violate the
specified limits.
Check if no battery is connected to the ouput.
Check if the connected load does not violate the
specified limits.