Legend: 

 

Z10b............wiring diagram of resistive with current converter or capacitive transmitter – 2 - wire without supply 
Z22..............wiring diagram of single resistant transmitter connection 
Z32..............wiring diagram of double resistant transmitter 
Z248............wiring diagram of EA SP 1-Ex with controller with current feedback - 230 V AC 
Z249a..........wiring diagram of EA SP 1-Ex with controller with resistant feedback - 230 V AC 
Z257d..........3-wire version of EPV - without power supply connection 
Z260c ..........wiring diagram of resistive transmitter with current converter -3-wire version with power supply 
Z269b..........wiring diagram of resistive transmitter with current converter or capacitive transmitter -2-wire version   
                     with power supply

 

Z525............wiring diagram of electric motor 24 V DC

 

Z524............wiring diagram of EA with electric motor  24 V AC

 

Z521d..........wiring diagram of SP1- Ex with controller and resistant feedback for electric motor – for 24 V AC

 

Z522d..........wiring diagram of SP1- Ex with controller and current feedback for electric motor – for 24 V AC

 

Z519d..........wiring diagram of SP1- Ex with controller and resistant feedback for electric motor – for 24 V DC

 

Z520d..........wiring diagram of SP1- Ex with controller and current feedback for electric motor – for 24 V DC

 

Z378a..........wiring diagram of resistive with current converter or capacitive transmitter 2 and 3 - wire with supply 
Z395............wiring diagram of  position switches for 3-phase electric motor 
Z396............wiring diagram of  thrust switches for 3-phase electric motor 
Z397............connection of 3-phase electric motor with terminated thermal protection. 
Z397a.......... connection of 3-phase electric motor with build in thermal protection 
Z398............connection of position switches - terminated release contacts - for  version with 3-phase electric  
                     motor 
Z491, Z491g.... wiring diagram of EA with electric motor  230 V AC 
Z479............wiring diagram of switches S1 – S4 
 
B1 ............  single resistant transmitter 
B2.............  double resistant transmitter 
B3.............  capacitive transmitter, or EPV 
E1 ............  space heater  
F1 ............  electric motor thermal protection 
F2 ............  space heater thermal switch 
I/U ............  input (output) current (voltage) signals 
M  .............  electric motor 
C  .............  capacitor 
N ..............  position controller 
R ..............  voltage-dropping resistor (for 230V only) 
S1  ...........  thrust switch "open" 
S2  ...........  thrust switch "closed" 
S3  ...........  position switch "open" 
S4  ...........  position switch "closed" 
S5  ...........  additional position switch "open" 
S6  ...........  additional position switch "closed" 
X  .............  terminal board 
Y...............  brake of electric moto 

 
1.  In  case,  that  output  signal  from  the  capacitive  transmitter  (wiring  diagram  Z248,  Z520d,Z522d)  is  not  used 
(incomplete circuit between terminal 81 and 82), it is required to connect clamps 81 and 82 by jumper (jumper is 
connected  at  manufacturing  plant  for  connecting  to  terminal  board  only).  By  using  output  current  signal  from 
capacitive transmitter it is needed to remove jumper. 
2. In the version equipped with the controller  device while using the feedback from transducer CPT; when using 
the output signal there has been no galvanic isolation of the signal from the input one! 
3.  In  case  that  galvanically  separated  output  signal  is  needed  it  is  necessary  to  use  galvanical  separation 
element  (is  not  part  of  delivery),  e.g.  NMLSG.U07/B  (producer  SAMO  Automation  s.r.o.).  After  discussion  this  
module could be supplied by EA producer. 
4.  Wiring  diagram  Z525  without  switch  S6  is  version  with  single  resistant  transmitter  connection  and  3  –  wire 
converter  without  power  supply.  Wiring  diagram  Z525  without  switch  S5,  S6  is  version  with  double  resistant 
transmitter. 
5. Wiring diagram Z524 without switch S6 is version with any position transmitter. Wiring diagram Z524 without 
switch S5, S6 is version with double resistant transmitter. 
 
6.  Wiring  diagram  Z491  without  switch  S6  is  version  with  optional  position  transmitter.  Wiring  diagram  Z491 
without switch S5, S6 is version with single resistant transmitter and 3 – wire converter without power supply. 

Summary of Contents for SP 1-Ex

Page 1: ...74 0720 02 74 0720 02 INSTALLATION SERVICE AND MAINTENANCE INSTRUCTIONS Explosion proof electric part turn actuators SP 1 Ex 1026...

Page 2: ...73 X Design and type tests are in accordance with the following standards EN 60 079 0 Electrical apparatus for explosive gas atmospheres Part 0 General requirement EN 60 079 1 Electrical apparatus for...

Page 3: ...it 16 4 2 Adjustment of position indicating unit Fig 3 16 4 3 Adjustment of resistant transmitter Fig 4 17 4 4 Adjustment of the Electronic Position Transmitter EPV the Resistive Transmitter Potentiom...

Page 4: ...overvoltage category In order to demonstrate the compliance with the requirements of the European Council directive on machinery 2006 42 EC European Parliament and Council Directive 2014 34 E on equip...

Page 5: ...IEC 60 079 7 tb identification of dust ignition protection by enclosure t according to EN IEC 60 079 31 II or III identification of the class of non explosive electric device according to the standar...

Page 6: ...fety e type of protection applied to electrical apparatus in which additional measures are applied so as to give increased security against the possibility of excessive temperatures and of the occurre...

Page 7: ...ature transmitting through junction component 5 Cable glands blinds are assigned only for transport and storage period i e for period till the actuator is builded into operation with danger of explosi...

Page 8: ...on protected from direct climatic effects such as direct sunlight Installation and operation of EA is possible in any position Vertical position of output part axis and with the control part above the...

Page 9: ...ration amplitude 19 6 m s 2 for f fp transition frequency fp is from 57 up to 62 Hz AH 2 medium impacts shocks and vibrations AG 2 with serious danger of plants and mould growing AK 2 with serious dan...

Page 10: ...hether during transport or storage the actuator was not damaged Compare also whether the parameters on their nameplates are in accordance with accompanying documentation or the Contract If any discrep...

Page 11: ...and max load torque Nm closing time s 90 operation stroke and electric motor parameters are given in Table 1 Table 1 Basic specifications Electric motor 3 Type number Operating speed 10 1 Operating st...

Page 12: ...C 4K Position transmitters Resistive position transmitter Resistance single B1 100 2 000 Operating life of transmitter 1 106 cycles Load capacity 0 5 W do 40 C 0 W 25 C Maximum current load 100 mA Max...

Page 13: ...Z 0 mA or 4 mA clamps 81 82 Values tolerance of output signal of EPV and capacitive transmitter Z 0 2 mA O 0 1 mA EPV and capacitive transmitter linearity error 1 5 1 EPV and capacitive transmitter h...

Page 14: ...relay 5A 250 V AC Digital outputs 4x LED supply error adjustment opening closing with two colour LED Error status control switch 24 V 2W POR Reaction at error situation transmitter error error message...

Page 15: ...lange clings to the valve gearing Fix the flange with four screws with mechanical ruggedness min 8G tightened to allow moving of EA Then the fixing screws tighten uniformly crosswisely 3 1 2 Mechanica...

Page 16: ...d N connect to the corresponding terminals In case of the three phase version connect the phase cables L1 L2 and L3 to U V W terminals 2 3 4 the protection cables to the marked places of internal and...

Page 17: ...transmitter and the sense of turning puts the EA to the positions open and closed measures inertia mass in the directions opening and closing and loads the adjusted parameters into the EEPROM memory...

Page 18: ...re in the production plant adjusted to a fixed angle according to the specification given on the nameplate While setting adjusting and resetting follow these steps Fig 3 In the version with a transmit...

Page 19: ...smitters is according to the customer s specification To adjust the transmitter follow these steps Loosen the fixing screws 9 of the transmitter holder and push the transmitter out of mesh Connect a m...

Page 20: ...h limit positions and repeat the procedure if needed Note The output signal of 4 20mA can be adjusted at the range from 75 up to 100 of the rated stroke stated on the actuator s nameplate At values le...

Page 21: ...tric actuators SP 1 Ex with controllers Note In case that reversed output signals are needed in the position OPEN minimum output signal contact personnel of service centres The capacitive transmitter...

Page 22: ...er of precision class 0 5 and loading resistance lower than 500 on the terminals 81 82 Follow the procedure described in the previous chapter A C Adjustment of the Capacitive Transmitter Served as a F...

Page 23: ...s they function as limit switches in case of position unit switching off failure or as protection against overload The procedure is as follows Loosen the counter nut of the stop end screw Z Rotate the...

Page 24: ...blink control signal 3 blinks 0 10V DC 1 blink EA opens receiving signal SYS 2 blinks EA closes receiving signal SYS 2 blinks response for signal SYS TEST 3 blinks EA stops receiving signal SYS 1 bli...

Page 25: ...ontroller with the D4 diode reports about the type of the error Else after finishing the initialisation process the controller is put into the regulation mode Error messages of the controller with D4...

Page 26: ...Changing or filling grease up during first years operation is not required To refill or to replenish the grease is needed during revisions Intervals between two prevention inspections are four years G...

Page 27: ...ion shaft 5 Fig 10 5 4 Troubleshooting At failure of power supply the EA stops in the position where it was before the failure If needed the EA can be set only with the manual control the hand wheel A...

Page 28: ...26 SP 1 Ex 7 Enclosures 7 1 Wiring diagrams Wiring diagrams EA SP 1 Ex...

Page 29: ...SP 1 Ex 27 Wiring diagrams EA SP 1 Ex with controller ERROR MESSAGE ERROR MESSAGE...

Page 30: ...28 SP 1 Ex...

Page 31: ...m of switches S1 S4 B1 single resistant transmitter B2 double resistant transmitter B3 capacitive transmitter or EPV E1 space heater F1 electric motor thermal protection F2 space heater thermal switch...

Page 32: ...Z398 must be specified in the order by words If it is not stated wiring diagram will be realized according to the scheme Z395 8 Terminal 20 22 24 and 26 are not moved in the scheme Z519d Z249a and Z5...

Page 33: ...SP 1 Ex 31 7 2 Dimensional drawings 7 2 1 Dimensional drawings flange connection Flange...

Page 34: ...Shape L xx Shape H xx Shape V xx Flange dimension D xx U L xx U H xx U V V xx W Z X D 14 14 L 14 14 H 14 14 22 V 20 20 0 22 5 6 0 D 17 17 L 17 17 H 11 11 16 V 17 17 0 19 5 6 0 D 16 16 L 16 16 H 8 8 1...

Page 35: ...SP 1 Ex 33 Coupling shape Pull rod TV360...

Page 36: ...r o Strojn cka 7 080 01 Pre ov Tel 421 0 51 7480 460 Fax 421 0 51 7732 096 E mail regada regada sk Czech Republic Exclusive representation Regada s r o Ltd for sale of electric actuators Regada esk s...

Reviews: