![REFUSOL 20K-2T Operating Manual Download Page 60](http://html1.mh-extra.com/html/refusol/20k-2t/20k-2t_operating-manual_1432921060.webp)
Error Messages and Troubleshooting
60
Main Menu (v2.6)
REFUsol 20K...33K-2T
982079 | 05 | 2021-03
ID57 OverTemp
-
Fault_Inv
The temperature
of the inverter is
too high.
Check that the inverter has been assembled and installed according to the specifica
-
tions in this manual.
Check the solar radiation conditions and the ambient temperature at the inverter.
Check the proper function of the cooler (dirt) and the function of the fans.
ID58 OverTemp
-
Fault_Boost
The boost temp is
too high.
ID59 OverTemp
-
Fault_Env
The ambient tem
-
perature is too
high.
ID60 PE Connect
Fault
Connection error
PE conductor.
Check secure contacting of the PE conductor.
ID61-
ID64
–
(Reserved)
–
Tab. 8:
Event list
with error and information messages
ID
Event name Event description Measure
Summary of Contents for 20K-2T
Page 71: ......