Technical data
Reflexomat with Basic controller — 20.06.2017 - Rev. C
English — 15
5
Technical data
5.1
Control unit
Note!
The following values apply for all control units:
– Permissible flow temperature:
– Permissible operating temperature:
– Permissible ambient temperature:
120 °C
70 °C
0 °C – 45 °C
Type
Power
output
(kW)
Power supply
(V / Hz , A)
Degree of
protection
Number of RS-
485 interfaces
I/O
module
Electrical voltage
control unit
(V, A)
Noise level
(dB)
Weight
(kg)
RC 200
0.75
230 / 50, 3
IP 54
1
No
230, 2
72
52
RSC 200
0.75
230 / 50, 3
IP 54
1
No
230, 2
<
59
52
RC 300
0.75
230 / 50, 3
IP 54
1
No
230, 2
72
69
RSC 300
0.75
230 / 50, 3
IP 54
1
No
230, 2
<
59
69
RC 400
0.75
230 / 50, 3
IP 54
1
No
230, 2
72
80
RSC 400
0.75
230 / 50, 3
IP 54
1
No
230, 2
<
59
80
RC 500
0.75
230 / 50, 3
IP 54
1
No
230, 2
72
93
RSC 500
0.75
230 / 50, 3
IP 54
1
No
230, 2
<
59
93
RS 90/1
individual
0.75
230 / 50, 3
IP 54
1
No
230, 2
72
25
RS 90/1
firmly fitted
0.75
230 / 50, 3
IP 54
1
No
230, 2
72
21