28
8540571 - 25/08/2016 - Rev.15
TECHNICAL SPECIFICATIONS
TECHNICAL SPECIFICATIONS OF VISION BARRIERS VX
Protected height
mm
160
– 1810
Resolutions
mm
20
– 30 – 40 – 50 – 90
Working range (selectable)
20, 30, 40, 50, 90mm and
Multibeam models
m
0
6 (low)
1
18 (high for models with integrated additional functions)
3
18 (high for Master-Slave models)
Working range (selectable)
LONG RANGE models
m
10
22 (low)
18
60 (high)
Safety outputs
2 PNP
– 500mA @ 24VDC
Response time
**
ms
5
28 (see tables for specific models)
Internal test frequency
every 500ms (2Hz)
Power supply
VDC
24
20%
Connections
Connectors M12 5/8-poles
Max. conn. length
m
100 (50 between Master and Slave)
Operating temperature
°C
0
55°C
Protection rating *
IP 65
Dimensions of section
mm
35 x 45
Max. consumption
W
2 (Emitter)
3 (Receiver)
Light curtain lifetime
20 years
Safety level
Type 2
IEC 61496-1:(ed.3)
IEC 61496-2:(ed.3)
SILCL 1
IEC 62061:(ed.1)
PL c - Cat.2
EN ISO 13849-1:2008
* Devices are not suitable for outdoor use without supplementary measures
** In case of operation of VISION VX in Master-Slave configuration, the correct total SLAVE response
time must be calculated according the following formula:
ttot_slave = tslave + tmaster + 1,8 ms
LEGENDA
VISION
(with additional functions)
= VX VISION Master = VXM
VISION Slave = VXS
20 mm Resolution Models
152
302
452
602
752
902
1052
1202
1352
1502
1652
1802
Number of beams
15
30
45
60
75
90
105
120
135
150
165
180
Response time (VX)
7
9
10
12
14
16
18
20
22
24
26
28
Overall barrier ht. mm
261
411
561
711
861
1011
1161
1311
1461
1611
1761
1911
PFHd *
1,02E-8 1,17E-8 1,33E-8 1,48E-8 1,63E-8 1,79E-8 1,94E-8 2,10E-8 2,25E-8 2,40E-8 2,56E-8 2,71E-8
DCavg
#
97,77% 98,07% 98,25% 98,38% 98,47% 98,53% 98,58% 98,63% 98,66% 98,69% 98,71% 98,73%
MTTFd
#
years
100
92,14
81,96
73,80
67,12
61,55
56,83
52,79
CCF
#
80%
30 mm Resolution Models
153
303
453
603
753
903
1053
1203
1353
1503
1653
1803
Number of beams
8
16
24
32
40
48
56
64
72
80
88
96
Response time (VX)
6
7
8
9
10
11
12
13
14
15
16
17
Response time
(VXM or VXS)
6
8
9
11
13
14
16
17
19
21
22
24
Overall barrier ht. mm
261
411
561
711
861
1011
1161
1311
1461
1611
1761
1911
PFHd *
9,58E-9 1,05E-8 1,14E-8 1,24E-8 1,33E-8 1,42E-8 1,51E-8 1,61E-8 1,70E-8 1,79E-8 1,88E-8 1,98E-8
DCavg
#
97,58% 97,84% 98,02% 98,16% 98,26% 98,34% 98,40% 98,45% 98,50% 98,53% 98,57% 98,59%
MTTFd
#
years
100
99,34
91,93
85,55
79,99
CCF
#
80%
* IEC 62061
#
ISO 13849-1