8540571 - 28/04/2008 - Rev.6
11
EMITTER CONNECTIONS
EVERY MODEL - 5 poles M12 connector (POWER-SUPPLY).
MASTER MODELS - 5 poles M12 Secondary connector.
PIN
COLOR
NAME
TYPE
DESCRIPTION
FUNCTIONING
1
Brown
24VDC
+24 VDC power supply
-
3
Blue
0VDC
0 VDC power supply
-
5
Grey
PE Ground
connection -
2
White
RANGE0
*
4
Black
RANGE1
*
INPUT
Barrier configuration
According the normative
EN61131-2 (ref. Table 2)
* OUTPUT only on MASTER Secondary connector
Table 1
TEST and RANGE SELECTION
PIN 4
PIN 2
FUNCTIONING
24VDC
0VDC
HIGH range (1 - 18m) (Master/Slave 3 - 18m)
0VDC
24VDC
LOW range (0 - 6m)
0VDC
0VDC
Emitter in test mode
24VDC 24VDC
Selection
error
Table 2
RECEIVER CONNECTIONS
SLAVE MODELS - 5 poles M12 connector (POWER-SUPPLY)
PIN
COLOR
NAME
TYPE
DESCRIPTION
FUNCTIONING
1
Brown
24VDC
-
+24 VDC power supply
-
3
Blue
0VDC
-
0 VDC power supply
-
5
Grey
PE - Ground
connection
-
2
White
OSSD1 OUTPUT
4
Black
OSSD2 OUTPUT
Safety static outputs
PNP active high
Table 3