CHARACTERISTICS OF THE OUTPUT CIRCUIT
For the output circuit, the safety relay uses two guided contact safety relays.
These relays are rated by the manufacturer for voltage and current values above those
indicated in the technical data; however, to assure correct insulation and to avoid damage
or premature aging, protect each output line with an appropriate fuse (depending on the
load). Check that load characteristics comply with the indications given in the table below.
Minimum switching voltage
18 VDC
Minimum switching current
20 mA
Maximum switching voltage
250 VAC
Maximum switching current
6 A (AC) / 6 A (DC)
STATUS INDICATORS
LED
COLOR
STATUS/COLOR
CONDITION
IN
Green
ON
ON with input activated
OFF
OFF with input not activated
Table 2
Figure 8