59
REER S.p.A. - Via Carcano, 32 - 10153 Torino, Italy - Internet: www.reersafety.com - e-mail: [email protected]
8541205 - rev
.1 - 02/09/2019
Technical specifications
TECHNICAL SPECIFICATIONS
TECHNICAL FEATURES
Safety
Type 4
EN 61496-1:2013 IEC 61496-2:2013
SIL 3
IEC 61508-1: (ed.2) IEC 61508-2: (ed.2) IEC 61508-3: (ed.2) IEC 61508-4: (ed.2)
PL e
EN ISO 13849-1:2015
Cat. 4
EN ISO 13849-1:2015
Range
0...8 m
Multibeam
2 / 3 / 4 beams
Power supply
24VDC ± 20%
Power consumption
3 W
Connections
Power supply connector on Active Element:
•
M12 - 5 Pin Male: (S-A models)
•
M12 - 8 Pin Male: (S models)
•
M12 - 12 Pin Male: (SM/SMO/SMP/SMPO models)
Muting sensor connectors / Muting lamp / Configuration:
•
M12 - 5 pin Female
Configuration
Hardware on Active Element connector S, SM, SMO models
Hardware or software with USB connection <-> PC on SMP, SMPO models
Conductor dimensions
0,25 ÷ 2,5 mm
2
(0,5 mm
2
with length > 20 m / 1 mm
2
with length > 50 m)
Max connections length
100 m
Safety Outputs (OSSDs)
2 PNP – 400mA @ 24VDC
STATUS Output
PNP – 100mA @ 24VDC (shows the condition of the OSSD outputs)
*
EDM input
Available on Active Element, selectable
*
Restart Auto/Manual
Available on Active Element, selectable
*
Response time
5,5 ms
Signals and diagnostics
LED Signals on Active Element Label
Models SMO, SMPO: Indication of MUTING / OVERRIDE / CURTAIN STATUS
with integrated lamp in the upper Active Element cap, LED technology
Operating temperature
-30°C ÷ +55°C
Degree of protection
IP 65 and IP 67
Section Size (l x h)
50mm x 55mm
* S-A models excluded