Operating Instructions

Reelcraft Industries, Inc.  •  2842 E Business Hwy 30, Columbia City, IN 46725

Ph: 800-444-3134 / 260-248-8188  •  Fax: 800-444-4587 / 260-248-2605

Customer Service: 855-634-9109  •  [email protected]  •  www.reelcraft.com

Form #1213-109   Rev: 5/2018

Heavy Duty Cord Reels - Condensed Version

Cord / Cable Reels

Series L 4000

Series L NM400 Series L 70000

Series L 5000

Series L 7000

Read these instructions carefully before attempting to install, operate or maintain 
this product. Only qualified persons should install this product. Failure to comply 
with instructions may result in personal injury and/or property damage. Every at-
tempt is made to ensure the accuracy and completion of these instructions; however, 
manufacturer is not responsible for ommissions. To obtain the complete version of 
service manuals, technical bulletins and support, please visit www.reelcraft.com or call 
customer service during business hours.

 

 Safety

1.  Ensure that power supply voltage does not 

exceed maximum voltage rating of reel. 
Also, ensure that reel is properly installed 
before connecting to power supply.

2.  All cord reels with flying leads must be 

hard wired to ensure proper function.

3.  Check for frayed/broken wires before each 

use.

4.  Do not exeed maximum installation height 

of 16 ft unless specified.

5.  A high tension spring assembly is con-

tained within the reel. 

Exercise extreme 

caution

.

6.  Remove all spring tension and electric 

power before beginning any disassembly 
process.

7.  If an electrical malfunction should occur, 

remove power from reel immediately.

8.  Ensure that reel, electrical cord, and equip-

ment being serviced are properly grounded. 
Use an ohmmeter to check ground continu-
ity.

9.  Reels that include explosion-proof fluores-

cent hand lamps are not explosion-proof 
themselves.

10.  The Ground Fault Circuit Interrupter Re-

ceptacle is designed to protect people from 
line-to-ground shock hazards. The GCFI 
does not protect against short circuits or 
overloads. This is the function of the fuse 
or circuit breaker. Test monthly.

11.  Pull electrical cord from reel by grasping  

the electrical cord itself, not the work de-
vice.

12.  If reel ceases to unwind or rewind, remove 

electrical power immediately. Do not jerk 
excessively on electrical cable!

13.  Treat and respect the cord reel as any other 

piece of machinery, observing all common 
safety practices.

        Installation

Ensure that only a qualified electrician installs/
services this equipment. Observe applicable 
NEC, OSHA, and local electrical codes when in-
stalling this equipment. Installation of GFCI cord 
reels should be performed by a qualified and 
licensed professional in accordance with local 
building codes and applicable NEC standards.

        Mounting & Guide Arm Adjustment

The cord reel is equipped for universal mount-
ing so that it can be mounted on a structurally 
sound floor, wall or ceiling; whichever provides
maximum performance. The guide arm must be
rotated to a position that allows the cord to feed 
through the roller brackets with minimal bend-
ing. Replace the fasteners. Where applicable, 
the U-Bolt must be placed in the proper location 
when rotating the guide arm, otherwise the reel 
might “latch out” during use. Refer to online 
manual for proper U-Bolt locations. 

        Lubrication

Cord reel spring and bearings are factory
lubricated and require no further lubrication.

        Install/Replace the Cord

CAUTION:

 Exercise extreme caution when add-

ing or removing spring tension. 

Ensure reel 

base is fastened down prior to adjusting 

tension.

 Do not move spool while tightening 

hose or latch will disengage. 
1.  Wind spool flange required number of turns 

to achieve proper tension (Refer to online 
Tech Bulletin). Do not over-tighten.

2.  Engage cord

 

latching mechanism

Remove access cover.

3.  Strip 4” to 8” of output electrical cord outer 

jacket.

4.  Route cord through U-Bolt*, cutout in 

spool, then through strain relief (90° 
elbow). Tighten U-Bolt* and strain relief 
(90° elbow) as required. *Where applicable; 
not all models contain a U-bolt.

5.  Using wire nuts, connect output electrical 

cord wires to collector assembly brush 
wires. Connect ground wire of output elec-
trical cable to ground lug.

6.  Check for ground faults using an ohm-

meter.

7.  Install access cover. Carefully release latch 

and firmly hold the cord while winding it 
onto reel. Install bumper stop at desired 
position.

        Spring Tension Adjustments

To adjust spring tension, add or remove wraps 
of cord from the spool, one wrap at a time, until 
desired tension is obtained (

refer to safety 

cautionary statements

). Cord latching 

mechanism can be removed for constant tension 
applications.

        Repairs

Extensive repairs should be performed only by 
the factory service center to avoid damage which 
may cause serious injury or void your warranty. 

CAUTION: 

Remove all spring tension and 

electrical power before disassembly process.

Series L 4000

Series L 5000

Series L 7000 

& L 70000

Series L NM400