Page | 2
Ascento 37 Export St Lytton QLD PH: 1800 807 604 | VSRM Inverter Contant Pressure Pumps | V2016.12
tank or a tank that is below the level of the pump) the VSRM pump must have “gravity fed water supply” –
otherwise known as flooded suction.
1.2.2. MAINS PRESSURE BOOSTING: This is a specialized type of application, and must be completed by a Qualified
Plumber or Pump Technician who is competent to perform this type of installation. The configuration MUST include
a ball-valve on the inlet pipe and compliant non-return valves on the inlet & outlet pipes, and comply with the
applicable Council/Shire plumbing specifications. Request the diagrammatic installation guide for MAINS PRESSURE
BOOSTING from [email protected]
1.4 Operating Conditions
1.
Liquid: unfrozen clean fresh water
2.
Liquid Temperature: 5
℃
to 50
℃
2. Safety Notices
2.1 Notice
1. Please read the manual carefully before installation and use, also read to the diagrammatic instructions in
conjunction with this instruction manual.
2. Pay attention to all safety warnings.
3. Warranty does not cover loss or damage caused by improper installation, improper use or unauthorised
modifications.
2.2 Pre-use Check
Every product is factory checked so it will be in good working order when you receive it. However please check;
1.
Ensure the model and type is what you have ordered, and is suited to your application.
2.
Check for damage caused by transportation, do not connect it to the power if it is damaged in any way.
2.3 Environmental Conditions
The installation conditions of VSRM Pumps has a direct impact on the function and service life, so the installation
surroundings should conform to the following conditions;
1.
The pump must be installed on a level concrete pad, or similar material that will remain level and not
subside.
2.
The pump must be housed in a well ventilated enclosure that protects it from sunlight and rain and it must
be in a well drained area, protected from the weather, dust, dirt, leaves, insects, rodents, reptiles etc, by
way of a pump cover or a weatherproof enclosure. Installation under eaves of houses is not an acceptable
level of protection from the weather.
3.
Ambient temperature for safe operation: 10
℃
to 40
℃
- do not allow the unit to freeze.
4.
Protect from splash from pools, overflowing gutters or garden taps or any other water source.
5.
Do not install near any device that might cause electromagnetic interference.
6.
Do not install near radioactive material or fuel.
7.
All Electrical installation must be completed by a licenced Electrician, all warranty is void if installed by an
unqualified person.
8.
Before operation of this product, the installer must ensure it is wired correctly, and that it is Earthed
correctly to a circuit protected by a Circuit Breaker with an integral RCD (Safety Switch).
9.
Pay attention to all safety warnings and instructions in the manual, failure to do so voids all warranty and
may lead to harm and danger to persons.
10.
Consider your bedrooms & your neighbours when installing, the VSRM are quiet in operation but installing
away from these areas will minimise the risk of any disturbance.
11.
The pump must be easily accessible for servicing and repairs if ever necessary – do not install in any of the
following areas: confined space, crawl space, under a house with enclosed base, roof or ceiling space, or in
any other area that makes it difficult or impossible to easily access the pump.
DANGER:
Risk of Electric Shock: Disconnect VSD from the power supply and
wait 5 minutes
to
allow any retained current to discharge before opening the VSD.