Reefe RPC32E Manual Download Page 4

www.

reefe

.com.au

Ascento Group Australia

© 

AI.062020

P: 1800 807 604

3

3

3

3

3

TROUBLESHOOTING GUIDE

1. Pump does not stop: 

a. Water leak higher than 1,5 I/min. at some point:

b. Check the installation, taps, WC, etc. To check toilets, ensure the stop cock is closed completely, do not use a visual check as this may be misleading.

c. Manual start switch (RESET) is blocked:

d. Act on it several times, in case the problem persists consult your dealer.

e. Breakdown on the electronic card: proceed to its substitution.

f.  Incorrect electric connection:

g. Verify the connections according to Fig.3.

2. Pump does not start:

a. Not enough water supply, the security system has been activated and the LED (FAILURE) is on: 

Check the water supply and restart the pump through the reset switch (RESET).

b. The pump is not hydraulically primed. The safety system against dry operation has been activated and the LED (LOW WATER) is on: 

Fill with water the inlet, drain the water surplus in the installation opening a faucet located to he same level of the pump - to diminish the pressure of the 

water column over the flow sensor - and restore the operation mode using the pushbutton RESET.

c. Pump is blocked:

LED (LOW WATER) is on, the security system is activated.When we act on the manual start switch (RESET) the LED (ON) is activated but the pump does 

not work: Consult your dealer.

d. Failure in the electronic circuit:

Switch off power supply, wait a few seconds and turn it on again. If the pump does not start immediately then replace the circuit.

e. Not electrical supply:

Check the proper electric feeding. The tension LED (POWER) should be on.

f.  Not enough pump pressure:

The security system has been activated and the corresponding LED (LOW WATER) is on. Check that the pump pressure is the one shown in the hydraulic 

connection table.

g. Air in the pump aspiration:

The pressure gauge will indicate a pressure lower than the nominal or constant oscillations. The security system will act by stopping the pump, the LED 

(LOW WATER) will be on.Check the sealing of the connections and O-ring of the aspiration conduct.

3. The pump starts and stops repeatedly:

a. Small leak in some point of the installation: Verify possible tap or WC tank leaks and repair them.

Reviews: