TDS METER PROBE PLACEMENT

 

The HM Digital

 

DM-1: Dual TDS Monitor is an important tool in monitoring the performance of your RO/DI 

system. It is also, being an electronic device, the only part of your RO/DI system which needs to be kept 
dry. Make sure when mounting the TDS meter using the included adhesive strips that a location away 
from any potential spills and direct sunlight is selected, ideally above your RO/DI system.  

While it is up to you where the two probes are installed we highly recommend the below con

guration: 

IN Probe:

 Installed between the RO membrane and DI resin Stage(s). This will allow you to monitor the 

TDS out of your RO membrane to ensure it is operating properly. The TDS reading out of the RO 
membrane should be <10 ppm. 

OUT Probe:

 Installed after the last DI resin stage. The reading after the DI resin should be 0 ppm at all 

times. A reading higher than 0 indicates that the resin has been exhausted are requires replacing.

HM DIGITAL

 

DM-1: DUAL TDS MONITOR - USAGE INSTRUCTIONS 

1. Press the “POWER” button to power on.  

2. To display the TDS level of the RO 

ltered water, slide the switch to the IN side. This reading can be 

used to monitor RO membrane performance. When this begins to rise above the usual reading, it is 
likely time to replace your RO membrane. 

3. To display the TDS level of the product (RO/DI) water, slide the switch to the OUT side. This reading 

can be used to monitor DI resin performance. Any reading higher than 0 TDS means you need to 
replace your DI resin. 

4. The displayed TDS will always be most accurate after approximately 10 seconds of running. 

5. Turn off the unit by pressing the “POWER” button. It will automatically shut off after 10 minutes.

It can also be useful to check your tap water TDS occasionally by moving one of the 

probes temporarily. Typically though there is no need to continue monitoring the tap TDS 

as the reading will seldom vary.

A full manufacturer instruction manual including more detailed installation notes is 
included with every TDS meter.

"

SYSTEM INSTALLATION

Summary of Contents for 6 Stage 400GPD Expert

Page 1: ...ER INSTALLATION INSTRUCTIONS 5 Connecting Disconnecting Quick Connect Fittings 5 Reverse Osmosis Membrane Installation 5 Re fi llable Deionisation Cartridge Installation 6 SYSTEM INSTALLATION 7 8 TDS...

Page 2: ...nspect every 6 months thereafter and after any system adjustments replacing as necessary Always turn off the source water connection to the RO DI system when not in use to prevent fl ooding in the eve...

Page 3: ...he wastewater line This water is not suitable for use in your reef aquarium as it contains all of the rejected salts that your RO membrane has fi ltered out However this system halves the wastewater r...

Page 4: ...Pressure Gauge 7 Dual In Line TDS Meter 1 2 3 4 5 6 7 INCLUDED PARTS Housing Wrench Feed Water Connector Colour Coded Tubing Wastewater Drain Connector 2x 200GPD Thin Film Composite Reverse Osmosis M...

Page 5: ...ng the cap and tightening 4 Reconnect the RO tubes ensuring they are connected back to their original connectors making sure to tighten the collets securely FILTER INSTALLATION INSTRUCTIONS It is crit...

Page 6: ...t you have left enough room for the foam insert and cap to replaced about 0 5 1cm 5 Make sure the threads are clear of any resin beads before replacing the bottom cap This will make it easier to screw...

Page 7: ...than 0 indicates that the resin has been exhausted are requires replacing HM DIGITAL DM 1 DUAL TDS MONITOR USAGE INSTRUCTIONS 1 Press the POWER button to power on 2 To display the TDS level of the RO...

Page 8: ...ble by the small piece of yellow tube which comes pre inserted this is just for your reference and can be discarded Measure the tube required to reach from this connector to the IN left side of the DI...

Page 9: ...n Filter 3 5 Micron Carbon Block Filter 4 Reverse Osmosis Membrane 5 Refillable Deionisation Resin Cartridge 6 Pressure Gauge 1 3 2 5 6 9 8 5 WASTE WATER PRODUCTION WATER SOURCE WATER 7 4 4 10 11 12 7...

Page 10: ...is the TDS value of the water being fed into the DI resin stage The higher the TDS reading of the water coming out of your RO membrane the more remaining contaminants your DI resin will need to fi lt...

Page 11: ...e get in touch and let us know how we can assist you 1300 110 805 contact reefpurero com au The system is switching off and on frequently during normal operation In some instances where source water p...

Reviews: