REED ST-9809 Instruction Manual Download Page 6

reedinstruments

www

com

6

Pantone 534 Blue

Pantone 123 Yellow

Pantone 485 Red

Pantone 123 Yellow

Pantone 534 Blue

Black

Rich Black - 

20/20/20/100

Blue -  100/80/30/5

Yellow - 0/27/100/0

Red - 10/100/100/5

Yellow - 0/27/100/0

Blue -  100/80/30/5

Only if you REALLY need them:

Pantone 534 Blue -  100/80/30/5

Pantone 485 Red - 10/100/100/5

Pantone 123 Yellow - 0/27/100/

Instrument Description

1.. Transformer.Jaw
2.. Trigger
3.. Function.Selector.Switch
4.. Frequency.Selection.Switch
5.. Data.Hold.&.Power.Button
6.. Max/Min.Button
7.. Zero/Relative.Button
8.. LCD.Screen
9.. Low.Battery.Symbol

10.. Zero/Relative.Symbol
11.. Data.Hold.Symbol
12.. Bar-graph.
13.. Max/Min.Hold.symbol
14.. Continuity.Symbol
15.. Unit.symbols
16.. V,.Ω,.or.Hz.input.Terminal
17.. COM.Terminal
18.. Hand.strap

All manuals and user guides at all-guides.com

all-guides.com

Summary of Contents for ST-9809

Page 1: ...om Model Black Pantone 534 Blue 100 80 30 5 Pantone 485 Red 10 100 100 5 Pantone 123 Yellow 0 27 100 Instruction Manual AC Digital Clamp Meter ST 9809 All manuals and user guides at all guides com a l...

Page 2: ...m Pantone 534 Blue 100 80 30 5 Pantone 485 Red 10 100 100 5 Table of Contents Safety 3 Features 3 Specifications 4 5 Instrument Description 6 Operating Instructions 7 11 AC Leakage Current Measurement...

Page 3: ...taking any in circuit resistance measurement be sure there is no power in the test circuit and discharge all capacitors Features Designed for the measurement of current leakage High resolution of 10...

Page 4: ...aph Range Selection Manual Overload indication Left most digit blinks Power Consumption 10mA approx Sampling Time Display 2 times sec Bar Graph 20 times sec Operating Temperature 10 to 50 C Operating...

Page 5: ...Accuracy 50 60 Hz Wide 400 1KHz 40mA 10 A 1 0 0 5mA 4 5 0 5mA 400mA 100 A 3 0 5 0mA 3 0 5 0mA 4A 1mA 4 0 0 1A 4 0 0 1A 40A 10mA 4 0 1 0A 4 0 1 0A 80A 100mA 2 5 1 0A 3 0 1 5A 80 100A1 100mA 5 0 1 0A 5...

Page 6: ...30 5 Pantone 485 Red 10 100 100 5 Instrument Description 1 Transformer Jaw 2 Trigger 3 Function Selector Switch 4 Frequency Selection Switch 5 Data Hold Power Button 6 Max Min Button 7 Zero Relative...

Page 7: ...you REALLY need them Pantone 534 Blue 100 80 30 5 Pantone 485 Red 10 100 100 5 Operating Instructions Turn the meter on by pressing the Hold Button AC Leakage Current Measurements Leakage Current Flow...

Page 8: ...Blue 100 80 30 5 Only if you REALLY need them Pantone 534 Blue 100 80 30 5 Pantone 485 Red 10 100 100 5 Out of Balance Leakage Current 1 Set the rotary switch to the desired range 2 Press the Trigger...

Page 9: ...al To enable the filter set the switch at the 50 60 position The filter s cut off frequency is set at 100Hz with an attenuation characteristic of approx 24dB octave Wide Position If the circuit under...

Page 10: ...measured 4 The measured value will appear on the LCD screen Resistance and Continuity Measurement 1 Set the rotary switch to 2 Insert the test leads into the input jacks 3 Connect the test prods of t...

Page 11: ...D Screen Press a second time and the minimum value appear Press the button a third time to disable the MAX MIN function Auto Power Off This meter will power off after 30 minutes of inactivity To disab...

Page 12: ...________________________________________ ________________________________________________ ________________________________________________ ________________________________________________ ____________...