![REED ST-8839 Instruction Manual Download Page 7](http://html1.mh-extra.com/html/reed/st-8839/st-8839_instruction-manual_1431244007.webp)
reedinstruments
www
com
7
MODE Button Function
This infrared thermometer measures Maximum (MAX),
Minimum (MIN), Differential (DIF), and Average (AVG)
Temperatures. Each time you take a reading, this data is
stored and can be recalled with the MODE button until a new
measurement is taken. When the trigger is pulled again, the
unit will begin measuring in the last mode selected.
Pressing the MODE button also allows you to access the
High Alarm (HAL), Low Alarm (LAL) & Emissivity (EMS)
Each time you press MODE, you advance through the
mode cycle. The diagram on the left shows the sequence
of functions in the MODE cycle
Switching Settings
1. C/F
2. LOCK ON/OFF
3. SET ALARM
Select the temperature units (°C or °F) by
using the°C/°F switch. To lock the unit on for
continuous measurement, slide the middle
switch
LOCK ON/OFF
to the right. If the
trigger is pulled while the unit is locked on, the
laser and backlight will be turned on if they have
been activated. When the unit is locked on, the
backlight and laser will remain on unless it is
turned off using the
Laser/Backlight
button on
the keypad. To activate the alarms, please slide the bottom switch
SET
ALARM
to the right. To set values for the High Alarm (
HAL
), Low Alarm
(
LAL
) and Emissivity (
EMS
), fi rstly activate the display by pulling the
trigger or pressing the
MODE
button, then press the
MODE
button until
the appropriate code appears in the lower left corner of the display, press
the
UP
and
DOWN
buttons to adjust the desired values.