non-Contact AC Voltage Measurements

WArnIng:

 Risk of Electrocution. Before use, always test the Voltage 

Detector on a known live circuit to verify proper operation.

1. Touch the probe tip to the hot conductor or insert into the hot side of 

the electrical outlet.

2. If AC voltage is present, the detector light will illuminate.

nOte:

  The conductors in electrical cord sets are often twisted. 

 

For best results, rub the probe tip along a length of the cord  

 

to assure placing the tip in close proximity to the live conductor.

nOte:

  The detector is designed with high sensitivity. Static electricity 

 

or other sources of energy may randomly trip the sensor.  

 

This is normal operation

Hold Button

The Data Hold function allows the meter to “freeze” a measurement for 
later reference
1. Press the “

DAtA HOlD

” button to “freeze” the display, the “

HOlD

” 

indicator will appear.

2. Press the “

DAtA HOlD

” button to return to normal operation.

Flashlight

Press and hold the top button to turn the flashlight on. Release the button 
to turn the flashlight off.

AutO POWer OFF

The auto off feature will turn the meter off after 15 minutes.
 

Summary of Contents for ST-118

Page 1: ...reedinstruments www com Black Pantone 534 Blue 100 80 30 5 Pantone 485 Red 10 100 100 5 Pantone 123 Yellow 0 27 100 Model ST 118 3 in 1 Pocket Autoranging Digital Multimeter Instruction Manual...

Page 2: ...ng CATIII 1000V UL approved 200mA 500V Resettable Fused current inputs and overload protection on all ranges Autoranging with auto power off Safety International Safety Symbols This symbol adjacent to...

Page 3: ...C or V AC 600V DC AC A mA AC DC 200mA 500V fast acting Resettable Fuse Resistance Diode Continuity Test 600V DC AC 5 Take care when making measurements if the voltages are greater than 25VAC rms or 35...

Page 4: ...0 8 rdg 5d 2 000k 20 00k 200 0k 1 2 rdg 5d 2 000M 5 0 rdg 5d 20 00M 10 0 rdg 5d MAX INPUT VOLTAGE 600V AC DC DIODE TEST Test current 1mA max open circuit voltage of 1 5V typical CONTINUITY CHECK Audi...

Page 5: ...ouch the black test probe tip to the negative side of the circuit Touch the red test probe tip to the positive side of the circuit 4 Read the voltage in the display DC AC Current Measurements 1 Set th...

Page 6: ...disconnect one side of the part under test so the rest of the circuit will not interfere with the resistance reading 4 Read the resistance in the display CONTINUITY CHECK WARNING To avoid electric sho...

Page 7: ...he detector light will illuminate NOTE The conductors in electrical cord sets are often twisted For best results rub the probe tip along a length of the cord to assure placing the tip in close proximi...

Page 8: ...e bottom cover and secure the screw REPLACING THE FUSE 1 Disconnect the test leads from the meter 2 Remove the test leads holder and top cover one screw 3 Pull the pcb 4 Lift the center circuit board...

Page 9: ..._____________ ________________________________________________ ________________________________________________ ________________________________________________ _______________________________________...