Indirect Measurement

This is used to determine a distance  
using two auxiliary measurements.  
Press the 

INDIRECT MEASUREMENT

button once, the 

 icon will appear

on the display.

Aim at the highest point and press 
the 

ON/MEASURE

 button to take the 

measurement. Holding the instrument  
as horizontal as possible press and hold the 

ON/MEASURE

 button to 

trigger continuous measurement, the horizontal line is measured and 
shown in the summary and secondary lines.

Three Point Measurement

Press the 

INDIRECT MEASUREMENT

button twice, the 

 icon will appear

on the display. Aim at the highest 
point (1) and press the 

ON/MEASURE

button to trigger the measurement. 
Holding the instrument as horizontal 
as possible press and hold the 

ON/MEASURE

 button to trigger 

continuous measurement and sweep 
the laser up and down over the ideal 
target point (2), press the 

ON/MEASURE

 button again to

confirm the value. Aim at the lower 
point (3) and press the 

ON/MEASURE

button to trigger the measurement. 
The results are shown in the summary 
and secondary lines at the same time.

www.

GlobalTestSupply

.com

Find Quality Products Online at:

[email protected]

Summary of Contents for R8010

Page 1: ...reedinstruments www com Model R8010 Instruction Manual INSTR INSTR Laser Distance Meter www GlobalTestSupply com Find Quality Products Online at sales GlobalTestSupply com ...

Page 2: ... Clear Button 6 Reference Level Setting 6 Backlight 7 Distance Unit Setting 7 Single Distance Measurement 7 Continuous Tracking Max Min Measurement 7 Addition Subtraction 8 Area Measurement 8 Volume Measurement 8 Indirect Measurement 9 Three Point Measurement 9 Measurement Storage 10 Troubleshooting 10 Care 10 Battery Replacement 10 www GlobalTestSupply com Find Quality Products Online at sales Gl...

Page 3: ...ards the sun Do not stare into the laser beam or direct it towards others Features Designed for one handed operation User selectable unit of measure imperial metric Laser target pointer Reference point selection front or rear of instrument Backlit multi line LCD display Calculates Area Volume and Sum of Lengths Addition Subtraction and indirect 2 3 point Pythagoras calculations Max Min functions C...

Page 4: ...ume Sum of Lengths 2 point indirect pythagoras 3 point indirect Internal Memory Yes up to 20 readings Response Time 2 secs Auto Shut off Yes after 3 mins Low Battery Indicator Yes Power Supply 2 AAA batteries Battery Life Up to 4 000 measurements Laser Class Class II Product Certifications CE RoHS IP54 Operating Temperature 14 to 122 F 10 to 50 C Storage Temperature 4 to 140 F 20 to 60 C Operating...

Page 5: ...f button Display Description 1 Laser is active 2 Reference level front 3 Reference level rear 4 Measurement indicator Area measurement Volume measurement Indirect measurement Indirect second measurement 5 Single distance measurement 6 Battery status 7 Memory history call up values 8 Instrument error warning 9 Continuous Max Min measurement 10 Primary display 11 Secondary display 12 Previous result...

Page 6: ...rs When measuring against non reflective and dark surfaces the measuring time may increase On and Off The On Measure button turns the instrument and laser on Press the CLEAR button for a few seconds to turn the instrument and laser off The instrument switches off automatically after three minutes of inactivity Clear Button This button cancels the last action and clears the display Reference Level ...

Page 7: ... measurement function tracking is used for the transferring of measurements In continuous measurement mode the meter can be moved to the target whereby the measured value is updated approx every 0 5 seconds The corresponding max and min values are displayed dynamically in the first and second line For example the user can move from a wall to the required distance while the actual distance can be r...

Page 8: ...firm you are in the correct mode Press the On Measure button to take the first measurement ie length press the On Measure button again to take the second measurement ie width Then the area surface is automatically calculated and displayed in the summary line on the display The previous measurement will be shown in the second line Volume Measurement Press the Area Volume button twice to enter Area ...

Page 9: ...ary lines Three Point Measurement Press the Indirect Measurement button twice the icon will appear on the display Aim at the highest point 1 and press the On Measure button to trigger the measurement Holding the instrument as horizontal as possible press and hold the On Measure button to trigger continuous measurement and sweep the laser up and down over the ideal target point 2 press the On Measu...

Page 10: ...rds Troubleshooting If error persists contact REED Instruments at info reedinstruments com Care Do not immerse the instrument in water Wipe off dirt with a damp soft cloth Do not use aggressive cleaning agents or solutions Handle the instrument as you would a telescope or camera Battery Replacement This instrument uses 2 AAA alkaline batteries The batteries need to be replaced when the battery sym...

Page 11: ..._____________________________ ________________________________________________ ________________________________________________ ________________________________________________ ________________________________________________ ________________________________________________ ________________________________________________ ________________________________________________ ___________________________...

Page 12: ..._____________________________ ________________________________________________ ________________________________________________ ________________________________________________ ________________________________________________ ________________________________________________ ________________________________________________ ________________________________________________ ___________________________...

Reviews: