Continuous, Max/Min Measurement

1.  While the meter is on, press and hold the Measure button to start  

Continuous Measurement. 

2.  While measuring the Maximum and Minimum measurements will 

appear on the first and second rows on the LCD. 

3.  Press the Measure button to stop taking measurements.  

The meter will automatically stop after taking 100 continuous 
measurements.

Data Records

1.  Press and hold the Feature button to access the last 10 recorded 

measurements. The Record Number icon will appear on the LCD.

2.  The records will appear in reverse order from the time they were 

taken. Press the Function button to scroll through them.

3.  Press the Measure or Clear button to return to single  

measurements. 

Battery Replacement

When the Battery Indicator is flashing you will need to replace the  
batteries. 

1.  Turn the meter off and remove the battery compartment door on 

the back of the meter.

2.  Insert new batteries observing correct polarity.
3.  Close the battery compartment door.

www.reedinstruments.com

1-877-849-2127 | [email protected]

 

Summary of Contents for R8002

Page 1: ...www com Model R8002 Laser Distance Meter Instruction Manual Black Pantone 534 Blue 100 80 30 5 Pantone 485 Red 10 100 100 5 Pantone 123 Yellow 0 27 100 www reedinstruments com 1 877 849 2127 info reed...

Page 2: ...ed them Pantone 534 Blue 100 80 30 5 Pantone 485 Red 10 100 100 5 Table of Contents Features 3 Specifications 3 Instrument Description 4 Operating Instructions 5 7 Setting the Reference Point 5 Area M...

Page 3: ...Volume Indirect measurement using Pythagoras Max Min Measurements Continuous Measurements Reference Setting Saves the last 10 measured records Specifications Measuring Range 0 05 to 45m Measuring Acc...

Page 4: ...534 Blue 100 80 30 5 Pantone 485 Red 10 100 100 5 Instrument Description 1 On Measure Button 2 Function Button 3 Unit Backlight Button 4 Reference Set Button 5 Clear Off Button Display Description 1...

Page 5: ...ear button to cancel Press the Backlight button to turn the backlight on and off Press and hold the Unit button to change the measuring units Different measuring functions will be displayed as symbols...

Page 6: ...he 2 Point symbol appears on the LCD 2 Aim at the top measurement point and press the Measure button to take the first measurement 3 Turn the meter horizontal and press the Measure button to take the...

Page 7: ...on to stop taking measurements The meter will automatically stop after taking 100 continuous measurements Data Records 1 Press and hold the Feature button to access the last 10 recorded measurements T...

Page 8: ...still appears contact REED Instruments at info reedinstruments com for repair Be sure to take care with the meter s mirror Avoid dirt scratches and solvents These may affect the accuracy and precision...

Reviews: