Temperature Measurements
1. To avoid electric shock, disconnect both test probes from any source
of voltage before making a temperature measurement.
2. Set the function switch to TEMP. Press the
MODE
button to change
between °C and °F.
3. Insert the Temperature Probe into the negative COM and the
positive V terminals, making sure to observe the correct polarity.
4. Touch the Temperature Probe head to the area to be measured. Keep
the probe touching the part under test until the reading stabilizes
(about 30 seconds).
5. The LCD will display the reading.
Note:
To avoid electric shock, be sure the thermocouple has been removed
before changing to another function.
Non-Contact AC Voltage Measurements
1. Set the rotary function switch to the V position.
2. Touch the probe tip to the hot conductor or insert into the hot side of
the electrical outlet. If AC voltage is present, the detector will light up.
3. The conductors in electrical cord sets are often twisted. For best
results, rub the probe tip along a length of the cord to assure placing
the tip in close proximity to the live conductor.
4. The detector is designed with high sensitivity. Static electricity or
other sources of energy may randomly trip the sensor.
Min/Max Recording
While in Manual Range, select the proper range before selecting MIN/MAX
to ensure that the MIN/MAX reading will not exceed the testing range.
Press the
MIN/MAX
button to select the minimum reading. Press the
MIN/MAX
button again to select the maximum reading. Press the
MIN/
MAX
button again to exit and resume normal measuring.
Relative Mode
Press the
REL
button for Capacitance Zero & Offset Adjustment.