Circuit On/Off Measurement
1. Set the Function Switch to the Ω position.
2. Insert the Red test lead to the VΩHz% Input and the Black test
lead in the COM Input.
3. Turn the circuit power off and discharge all residual charges to
ensure accuracy.
4. Connect the test leads to the two terminals under test. The meter
will beep if the resistance is ≤10Ω. If the resistance is ≥150Ω the
meter will not beep.
Diode Measurements
1. Set the Function Switch to the Ω position.
2. Insert the Red test lead to the VΩHz% Input and the Black test
lead in the COM Input.
3. Turn the circuit power off and discharge all residual charges to
ensure accuracy.
4. Connect the test leads to the circuit under test. “OL” will appear
on the LCD if the diode is an open circuit or if polarity is reversed.
Capacitance Measurements
1. Set the Function Switch to the Ω position.
2. Insert the Red test lead to the VΩHz% Input and the Black test
lead in the COM Input. The LCD will display a measurement,
which is the internal fixed capacitance value. When measuring
small range gear capacitance, that value needs to be subtracted
from the measured value to ensure accuracy. The REL function
can be used to automatically subtract the value.
3. Connect the test leads to the circuit under test. Measurements
≥10μF will take several seconds to stabilize. To avoid damage or
injury do not apply voltages above 60 DC or 30 AC RMS.