Error Codes

If the meter fails its internal diagnostic test all button functions will cease 
and an error message will appear on the display.

1.  Err1: Pressure value is over the range.
2.  Err2: Pressure value is below the range.
3.  Err3: DIF function, the differential pressure value is over range.
4.  Err4: DIF function, the differential pressure value is below range.

Battery Replacement

When the battery power falls low, “BAT” will appear on the display screen. 
Immediately replace the 9V battery.

1.  Turn unit off
2.  Carefully open battery compartment at the back of the instrument
3.  Remove old battery
4.  Replace with new battery observing the correct polarity
5.  Close battery compartment

Notes   _________________________________________
________________________________________________
________________________________________________
________________________________________________
________________________________________________
________________________________________________
________________________________________________
________________________________________________

 

REED Instruments

1-877-849-2127 | [email protected] | www.reedinstruments.com

Summary of Contents for R3002

Page 1: ...m Model Black Pantone 534 Blue 100 80 30 5 Pantone 485 Red 10 100 100 5 Pantone 123 Yellow 0 27 100 Instruction Manual Digital Manometer R3002 REED Instruments 1 877 849 2127 info reedinstruments com www reedinstruments com ...

Page 2: ...e 485 Red 10 100 100 5 Table of Contents Features 3 Specifications 3 4 Instrument Description 4 5 Operating Instructions 5 7 Turning the unit on 5 Zero Adjust and Offset 5 Data Hold 5 Record 6 Backlight Display 6 Automatic Power Off 6 Units 6 Error Codes 7 Battery Replacement 7 For service on this or any other REED product or information on other REED products contact REED Instruments at info reed...

Page 3: ...l LCDs with backlighting Max Min Avg record with time stamp Data Hold freezes the displayed reading Low battery indication with auto power off Push button zero adjust and offset readings USB output Specifications Function Range Resolution Function Range Resolution inH2 0 138 3 0 1 ozin2 80 00 0 01 psi 5 000 0 001 ftH2 0 11 53 0 01 mbar 344 7 0 1 cmH2 0 351 5 0 1 kPa 34 47 0 01 kgcm2 0 351 0 001 in...

Page 4: ...esponse Time 0 5 seconds Low Battery Indicator Yes Over range Indicator Err1 Under range Indicator Err2 Operating Conditions 0ºC to 50ºC Storage Conditions 10ºC to 60ºC Serial format Baud rate 9600 Baud 8 Data Bits Power Supply Single 9V alkaline battery Includes USB cable tubing hard carrying case battery Optional Accessories Tripod model BS 6 Instrument Description 1 UNITS 2 DIF 3 REC 4 HOLD 5 B...

Page 5: ...t to the last setting used during operation Zero Adjust and Offset To Zero Adjust and Offset the meter turn the meter on without any fitting attached Press the HOLD button for about 2 seconds to zero the meter The meter will reset displaying 0 0 0 0 on the LCD screen changing to 0 000 If you want to offset the meter and display press the DIF button while taking a measurement Subsequent readings wi...

Page 6: ... button a third time to display the minimum MIN reading with the relative time 4 Press the REC button a fourth time to display the average value AVG reading with the relative time 5 Press the REC button a fifth time to continue recording MAX MIN AVG measurements 6 To exit the MIN MAX AVG mode press the REC button for 3 sec onds to return to normal operation Backlight Display Press the Backlight bu...

Page 7: ...differential pressure value is below range Battery Replacement When the battery power falls low BAT will appear on the display screen Immediately replace the 9V battery 1 Turn unit off 2 Carefully open battery compartment at the back of the instrument 3 Remove old battery 4 Replace with new battery observing the correct polarity 5 Close battery compartment Notes ___________________________________...

Page 8: ..._______________________ ________________________________________________ ________________________________________________ ________________________________________________ ________________________________________________ ________________________________________________ ________________________________________________ ________________________________________________ _________________________________...

Reviews: