Instrument Description

1.  IR Sensor
2.  Laser Pointer
3.  LCD Display
4.  °C/°F Button
5.  Max/Min Button
6.  Laser & Backlight Button
7.  Trigger
8.  Battery Cover

Display Description

1.  Measuring Indicator
2.  Data Hold
3.  Laser Pointer
4.  Fixed Emissivity Symbol
5.  Temperature Unit
6.  Low Battery Indicator
7.  Max/Min Readout
8.  Max/Min Symbol
9.  Digital Readout

 

REED Instruments

1-877-849-2127 | [email protected] | www.reedinstruments.com

Summary of Contents for R2002

Page 1: ...Model R2002 Infrared Thermometer Instruction Manual Black Pantone 534 Blue 100 80 30 5 Pantone 485 Red 10 100 100 5 Pantone 123Yellow 0 27 100 REED Instruments 1 877 849 2127 info reedinstruments com...

Page 2: ...nly if you REALLY need them Pantone 534 Blue 100 80 30 5 Pantone 485 Red 10 100 100 5 Table of Contents Safety 3 Features 3 Specifications 4 Instrument Description 5 Operating Instructions 6 7 Battery...

Page 3: ...ye of an animal Do not shine the laser beam off of a reflective surface into your eye Do not direct the laser beam towards any gas that can explode Features Precise non contact temperature measurement...

Page 4: ...e 1 sec Emissivity 0 95 fixed value Field of View Approx 8 1 distance to spot ratio with 90 encircled energy at focal point Diode Laser Output 1mW Wavelength 630 670nm class 2 II Laser product Spectra...

Page 5: ...534 Blue 100 80 30 5 Pantone 485 Red 10 100 100 5 Instrument Description 1 IR Sensor 2 Laser Pointer 3 LCD Display 4 C F Button 5 Max Min Button 6 Laser Backlight Button 7 Trigger 8 Battery Cover Disp...

Page 6: ...after approximately 8 seconds of inactivity Notes The meter will take up to 30 minutes to adjust from high ambient temperatures to low ambient temperatures Not recommended for measuring shiny or polis...

Page 7: ...es from the target the diameter of the object under test must be at least 1 inch in size The target needs to be larger than the unit s spot size The smaller the target the closer you should be to it W...

Page 8: ...______________________ ________________________________________________ ________________________________________________ ________________________________________________ ______________________________...

Reviews: