background image

6

www.REEDINSTRUMENTS.com

Instrument Description

1.  Laser Pointer Beam
2.  IR Sensor
3. Trigger
4.  Battery Cover
5.  Tripod Mount

6.  LCD Display
7.  Mode Button/Down Arrow
8.  Set Button
9.  High/Low Alarm Button/ 

Up Arrow

10. Laser ON/OFF Button

-26~1472°F / -32

~800°C

D:S=30:1

1.2@36

0.9@12

2.5@60

30@900

24@300

62@1500

R2320

Profess

ional

Infrared

 Thermometer

www.REEDINSTRU

MENTS.co

m

 

REED Instruments

1-877-849-2127 | [email protected] | www.reedinstruments.com

Summary of Contents for R2320

Page 1: ...www REEDINSTRUMENTS com Infrared Thermometer Instruction Manual R2320 REED Instruments 1 877 849 2127 info reedinstruments com www reedinstruments com...

Page 2: ...nd Differential Functions 10 Turning Laser On Off 10 Setting the High Temperature Alarm 11 Setting the Low Temperature Alarm 11 Adjusting Emissivity 12 Switching the Unit of Measure F C 12 Audible Ala...

Page 3: ...tributor or authorized Service Center Please note an additional fee for this service will apply Safety Never attempt to repair or modify your instrument Dismantling your product other than for the pur...

Page 4: ...ount for continuous monitoring Low battery indication and auto shut off Included Carrying Case Battery Specifications Temperature Range 26 to 1472 F 32 to 800 C Accuracy Basic 1 8 of reading or 3 6 F...

Page 5: ...s Laser Class Class II Low Battery Indicator Yes Power Supply 9V Battery Battery Life Approx 10 hours with continuous use backlight on Product Certifications CE RoHS Operating Temperature 32 to 122 F...

Page 6: ...6 LCD Display 7 Mode Button Down Arrow 8 Set Button 9 High Low Alarm Button Up Arrow 10 Laser ON OFF Button 26 1472 F 32 800 C D S 30 1 1 2 36 0 9 12 2 5 60 30 900 24 300 62 1500 R2320 Professional In...

Page 7: ...perature Measurement Alarm Indicator Low Battery Temperature Measurement Active Measurement Data Hold Unit of Measurement Temperature Measurement Value Temperature Measurement Value from Selected Mode...

Page 8: ...8 www REEDINSTRUMENTS com Distance Spot Size 4 REED Instruments 1 877 849 2127 info reedinstruments com www reedinstruments com...

Page 9: ...ment time to be set from 1 minute to 5 hours Refer to Trigger Lock Setup for details Note This function is applicable for processes that require regular moni toring of temperature 1 Once the trigger l...

Page 10: ...modes are shown in the secondary display area Turning Laser On Off Press the button to turn the laser indicator function ON and OFF When it is turned on the laser indicator will be displayed on the L...

Page 11: ...after 10 seconds of inactivity or if the trigger is pulled at any time Setting the Low Temperature Alarm Press the SET button twice to enter the low alarm limit setup The meter will automatically defa...

Page 12: ...ity values Press the UP and DOWN buttons to add or subtract 0 01 unit and or hold the UP and DOWN buttons to add or subtract 0 1 The instrument will exit the setup after 10 seconds of inactivity or if...

Page 13: ...t press the UP or DOWN buttons Press the a third time to confirm the entered time stamp The instrument will exit the setup after 10 seconds of inactivity or if the trigger is pulled at any time Turnin...

Page 14: ...ure value is normal When the HI LO limit alarm function is turned on and the measured temperature value is within the high and low alarm limit range the green LED lights up and the OK indicator is dis...

Page 15: ...trical circuit breaker boxes equipment Calibration and control of heater and oven temperatures Monitoring materials in processes involving heating and or cooling Quality control monitoring Research an...

Page 16: ...t Measure the temperature of the tape or painted surface Measured Surfaces Emissivity Metal Aluminum Oxidization 0 2 0 4 A3003 Alloy Oxidization Rough 0 3 0 1 0 3 Brass Burnishing Oxidization 0 3 0 5...

Page 17: ...t 0 7 Carbon Non Oxidization Graphite Silicone Carbide 0 8 0 9 0 7 0 8 0 9 Ceramics 0 95 Clay 0 95 Concrete 0 95 Cloth 0 9 Glass Convex Smooth Lead Boron 0 76 0 8 0 92 0 94 0 78 0 82 Plates 0 96 Stone...

Page 18: ...Laser fails to work weak laser Low battery Replace the battery Inaccurate measurement Wrong emissivity setting measured distance is too far measured target diameter is less than 20mm etc Verify field...

Page 19: ...77 849 2127 or by email at info reedinstruments com to discuss the claim and determine the appropriate steps to process the warranty Product Disposal and Recycling Please follow local laws and regulat...

Page 20: ...www REEDINSTRUMENTS com TEST MEASURE WITH CONFIDENCE CHECK OUT OUR LATEST PRODUCTS REED Instruments 1 877 849 2127 info reedinstruments com www reedinstruments com...

Reviews: