PURE DIVERTER SYSTEM
page 4 of 4
INSTALLATION INSTRUCTIONS
Plumbers, please ensure a copy of the installation
instructions is left with the end user for future reference
Tapware is to be installed by a Licensed Plumber in
accordance with AS/NZS 3500:2003
Recommended working water pressure 300-500 kpa.
Maximum water temperature is 65 deg.c.
DRESS FINISHING AND HANDLE ADJUSTMENT
- Prior to fit off ensure the correct size cut out around the Mixers (100mm centres) has been achieved.(see Fig.1)
- Remove the protective Cover from the Diverter. Ensure the Oring is intact and the installation is clean and free from any debri.
- Apply sealant to the outside of the Cover Flange and fit to the Diverter.
- Fit the Handles onto the Adjustment Fitting.
- If adjustment is required, remove the Handles and loosen the Set Screws of the Adjustment Fitting.
- Wind the Adjustment Fitting to reduce or increase the gap between the Wall and the Handle. (see Fig.2)
NOTE: Extensions may be acquired if correct installation can not be achieved.(Contact manufacturer)
- Once the gap from the Wall to the Handle is between 2-3mm, remove the Handle and tighten the Set Screws of the Adjustment Fitting.
- When securing the Handle adjustment Fitting, ensure the Set Screws are tightened onto the flats of the Cartridge Extension. (see Fig.2)
- Do not tighten the Set Screws on the threads of the Cartridge Extension.
- Fit the Handle so the Set Screw is positioned at the bottom. (tighten well)
- Note the Set screw must engage in the grove of the Adjustment Fitting.
Combined wall
thickness
not to exceed 25mm
NOGGING
Wall
Stud
Hot
Set Screw
28-32mm
Set Screws must
be tightened onto
the Flats of the
Cartridge extension
Cartridge
Extension
Wall cut out
47 - 52mm
Round
FRONT FACE
OF
WALL STUD
Apply
Sealant
Handle
Body
Cover
Flange
Set
Screw
Handle
Adjustment
Fitting
Finished
wall
surface
Cartridge
Extension
Set Screw Flat
Handle
Adjustment
Fitting
Fig.1
Fig.2
FIT OFF
ORING
page 4 of 4