PURE DIVERTER SYSTEM

page 4 of 4

INSTALLATION INSTRUCTIONS

Plumbers, please ensure a copy of the installation 

instructions is left with the end user for future reference

Tapware is to be installed by a Licensed Plumber in 
accordance with AS/NZS 3500:2003

Recommended working water pressure 300-500 kpa. 
Maximum water temperature is 65 deg.c.

DRESS FINISHING AND HANDLE ADJUSTMENT 

- Prior to fit off ensure the correct size cut out around the Mixers (100mm centres) has been achieved.(see Fig.1)
- Remove the protective Cover from the Diverter. Ensure the Oring is intact and the installation is clean and free from any debri. 
- Apply sealant to the outside of the Cover Flange and fit to the Diverter.

- Fit the Handles onto the Adjustment Fitting.
- If adjustment is required, remove the Handles and loosen the Set Screws of the Adjustment Fitting.
- Wind the Adjustment Fitting to reduce or increase the gap between the Wall and the Handle. (see Fig.2)

NOTE: Extensions may be acquired if correct installation can not be achieved.(Contact manufacturer)

- Once the gap from the Wall to the Handle is between 2-3mm, remove the Handle and tighten the Set Screws of the Adjustment Fitting.
- When securing the Handle adjustment Fitting, ensure the Set Screws are tightened onto the flats of the Cartridge Extension. (see Fig.2) 
- Do not tighten the Set Screws on the threads of the Cartridge Extension.
- Fit the Handle so the Set Screw is positioned at the bottom. (tighten well)
- Note the Set screw must engage in the grove of the Adjustment Fitting.

Combined wall 

thickness 

not to exceed 25mm

NOGGING

Wall

Stud

 

Hot

Set Screw

28-32mm

Set Screws must 

be tightened onto 

the Flats of the 

Cartridge extension

Cartridge

Extension

Wall cut out

47 - 52mm

Round

FRONT FACE 

OF 

WALL STUD

Apply 

Sealant

Handle

Body

Cover

Flange

Set

Screw

Handle 

Adjustment

Fitting

Finished 

wall

surface

Cartridge 

Extension

Set Screw Flat

Handle

Adjustment

Fitting

Fig.1

Fig.2

FIT OFF

ORING

page 4 of 4