background image

of 02

2

3

1

1

2

2

2

1

1

Assemble supplied P-Trap 

(1)

.   

Cut a required length of 40Ø mm PVC expansion coupling 

(2)

 and 

insert into P-Trap 

(1)

File down exposed end of 40Ø mm PVC 

(2)

.   

Attache (X) 

(3)

 to filed end of 40Ø mm PVC 

(2)

      Note: Ensure inner walls are lubricated. 

 

 

Lubricate Expansion Coupling 

(1)

 seal. 

Align 40mm PVC pipe 

(2)

 with Expansion Coupling 

(1)

 on wall to 

locate Basin against wall.   

Check and mark location of Expansion Coupling 

(1)

 for 

connection into waste pipe prepared in wall. 

Ensure height of 40mm PVC pipe is not more than 705mm 
maximum off floor. This will ensure waste pipe clears basin 
access panel cut out.  

Test fit lower basin rubber beneath Basin but use only if floor 
surface allows basin to be pushed back to wall.

  

Apply silicon to rear of Basin and complete installation. 

Note: When installation is complete be sure to check for 
leaks.

 

Fit recommended Waste 

(1)

 to the underside and top of Basin. 

Fit Square Cap 

(2)

 into top of Waste in place of push button 

supplied with waste. 

We recommend the use of soapy water or approved cleaners. This product should not be cleaned with abrasive materials.
Damage caused by any improper treatment is not covered by the product warranty. Refer to Warranty Conditions.

Care Details

Ensure a copy of the Installation Instruction is 
left with the end user for future reference.

Complete 

3

2

1

1

X

X

X

1

2

1

Assemble supplied P-Trap 

(1)

 to 40mm waste thread 

(2)

 under 

Basin.   

Cut a length of 40Ø mm PVC pipe 

(3)

 and insert into    P-Trap 

(1)

File down exposed end of 40Ø mm PVC 

(3)

 to fit Expansion 

Coupling. 

1

1

2

705

Max Height

Revision 2  Date: 18/10/2021   

Plumbers, please ensure a copy of the installation 
instruction is left with the end user  for future reference. 

Page 02