IMPORTANT:

This booklet should be left with the user after 

installation and demonstration

7.5/8.5/9.5/10.5kW

VITAL

Installation and User Guide

Summary of Contents for Vital RVLS10

Page 1: ...44 0 844 372 7766 Technical Service Email Service request redringxpelair com Calls cost 7p per minute plus your telephone company s network access charge DATE OF PUBLICATION 23 06 2017 Rev B IMPORTANT This booklet should be left with the user after installation and demonstration 7 5 8 5 9 5 10 5kW VITAL Installation and User Guide ...

Page 2: ...ed physical sensory or mental capabilities or lack of experience and knowledge if they have been given supervision or instruction concerning use of the appliance in a safe way and understand the hazards involved The shower spray head MUST be cleaned regularly to remove scale and debris The frequency of the cleaning will vary according to the local water quality If the water outlet temperature beco...

Page 3: ...of limescale It is the responsibility of the installer to check that the installation parameters meet the requirements of the products and any relevant regulations It is important that the routine checks are completed before calling us out as many issues can be simply diagnosed and resolved If we are called out to a fault which is subsequently identified as being an installation fault we will make...

Page 4: ... things to check 1 Check the mains water supply is fully open at the isolation valve 2 Check that the mains water supply is turned on at the isolation valve 3 Check that the front cover is correctly mounted on the back plate and all cover screws are fitted correctly Q Water too HOT A Six possible reasons 1 Reduce the temperature by adjusting the rotary temperature control 2 Clean the shower handse...

Page 5: ...rvicing switch off the electricity supply at the isolation switch Switch off the mains water supply at the isolation valve The inlet filter is situated inside the water inlet housing To gain access pull the filter from the inside of the inlet housing To reassemble follow procedure in reverse DO NOT over tighten the filter tray on reassembly 3 How Your Shower Works 4 Routine Maintanance ATTENTION D...

Page 6: ...on A piece of insulating or masking tape applied to the wall before marking out the fixing holes will help stop the drill from wandering particularly on tiled surfaces When working near a basin or bath insert the plug in the waste fitting so that small parts cannot be lost Take care not to drop accessories or tools into basin or bath TIPS Wall fixing points 15 1 Switch on the electrical supply at ...

Page 7: ...e the sealing rubber The shower spray head MUST be cleaned regularly to remove scale and debris The frequency of the cleaning will vary according to the local water quality If the water outlet temperature becomes hot and you are unable to obtain cooler water immediately check the shower handset for blockage See section 4 for cleaning instructions In order to avoid damage to your shower the electri...

Page 8: ... accordance with BS EN 806 A double check valve must be fitted with all flexible shower accessories where it is possible that the shower handset may come into contact with used water i e In the bath or shower tray IMPORTANT Before turning on the water supply to the shower unit the water supply pipe should be flushed out to remove debris After flushing the pipework ensure that the shower unit is po...

Page 9: ...tor must have an earthing sleeve fitted 3 Connect the cable to the terminal block Ensure that ALL the retaining screws are VERY tight and that NO cable insulation is trapped under the screws Loose connections can result in cable overheating IMPORTANT Failure to ensure that the retaining screws are VERY tight could result in a failure of the terminal block IMPORTANT DO NOT switch on the electricity...

Page 10: ... Electrical Connections Cont 11 Installation Guide 1 Establish position for the riser rail and mark the wall for the lower mounting bracket Make allowances for the tallest person likely to use the shower regularly 2 Remove covers from the wall brackets 3 Position the top bracket and mark the wall for the screw fixing Drill plug the wall and fix the top bracket 4 Fit the rail into the top bracket P...