Redring Active 320S Installation And User Manual Download Page 6

 

WHAT TO DO IF THINGS GO WRONG (2) 

REDRING AFTER SALES SERVICE 

Water continues to 
flow when                  

“  (stop)” selected 

This is normal.                                                                                                   
The shower includes a shutdown feature that means the water will continue to 

flow for up to 3 seconds after “  (stop)” has been selected. 

Broken parts 

Please contact our spares department on 08709 000420 (UK only). 
Fitting instructions are provided with most spares 

PROFESSIONAL SERVICE 

 

If the previous “Self Help” checks fail to restore the performance, you should seek professional help. 

 

The person who installed the shower is probably the best one to repair it and is certainly the person 
to contact if you have had a problem in the guarantee period. 

 

The following additional checklist is provided for the benefit of the qualified service person. 

 

WARNING: SWITCH OFF THE ELECTRICITY AT THE LOCAL ISOLATOR                                           

BEFORE REMOVING THE COVER TO MAKE CHECKS 

 

Water too HOT 

Water flow restricted by blockage in filter of solenoid valve. 
Switch off water, loosen inlet connection to solenoid, remove filter in solenoid 

with long nosed pliers and flush clean. 

Water too COLD 

Check circuit through thermal cut-out. 

Check circuit through microswitches on the pressure switch. 
Check each element circuit. 
Check tightness of electrical connections. 

No control over  

water flow 

Check Drive Gite is correctly engaged into Control Knob (see diagram.9) 

Undo headworks of stabiliser valve. 
Check stabiliser is in place and remove any debris in valve. 

Water leaks from 

burst pressure     

relief valve 

Check for cause of high pressure and remove it. 
Blockage on outlet e.g. blocked shower handset.  

Replace the pressure relief disc (not covered by guarantee). 

Water does not 
flow when outer 
knob “A” is 

turned. 

Check circuit through solenoid coil. If defective then replace. 
Check circuit through microswitches. If defective then replace. 
Power supply not reaching shower. 

 

 

 

We offer a technical advisory service on the telephone to 
contractors and other customers with problems in the field. 

 

 RING 08709 000430 (UK ONLY) 

RING YOUR LOCAL DEALER (Export Variants) 

 

Some spare parts (see later section) can be supplied 
against Credit or Debit cards. 

 

RING 08709 000420 (UK ONLY) 

 

Remember to quote the exact type of shower, as written on the 
front of the shower and on this leaflet.                                                     

Summary of Contents for Active 320S

Page 1: ...IMPORTANT This booklet should be left with the user after installation and demonstration REDRING ACTIVE 320S SMART TECHNOLOGY ELECTRIC SHOWER Installation and User Guide ...

Page 2: ... electric shower incorporating our Smart Technology and a unique dual control combining on off power select and flow temperature control Your shower is designed to stabilise temperature changes caused by water pressure fluctuations These can result from toilets being flushed or taps being turned on and off When this happens your showering temperature will be held within a controlled band provided ...

Page 3: ...ture setting to your liking has been achieved inner knob B will rarely need adjusting You must however take into account required adjustments for variations of incoming mains water temperature between summer and winter see Effect of Seasonal Incoming Water Temperature Changes 6 When you have finished showering turn outer knob A anti clockwise to the stop position Water will continue to flow for up...

Page 4: ...ed off It will reset itself if water is run through the shower for 10 to 20 seconds 7 The pressure relief device is to safeguard against abnormal pressure conditions Effect of Seasonal Incoming Water Temperature Changes The required water temperature is achieved by adjusting the rate of water flow Diagram 3 shows the principle involved in relating temperature rise to flow rate The higher the water...

Page 5: ...ermal cut out safety device to operate Turn inner knob B anti clockwise in the direction of the blue arrows to increase water flow Slowly increase the water temperature by turning inner knob B clockwise in the direction of the red arrows until a comfortable showering temperature has been reached You MUST WAIT approximately 20 seconds for each adjustment to affect the water temperature medium setti...

Page 6: ...id with long nosed pliers and flush clean Water too COLD Check circuit through thermal cut out Check circuit through microswitches on the pressure switch Check each element circuit Check tightness of electrical connections No control over water flow Check Drive Gite is correctly engaged into Control Knob see diagram 9 Undo headworks of stabiliser valve Check stabiliser is in place and remove any d...

Page 7: ...al and level with or a maximum of 0 6 metres 2ft below the top of the riser rail Choose a flat piece of wall to avoid the possibility of distorting the backplate thus making the front cover a poor fit 3 Adjust the position to get the most convenient arrangement taking the following into account The possible need to use the handset over the sink for hair washing etc The heater must not be mounted i...

Page 8: ...BEFORE CONNECTING THE PIPE WORK TO THE SHOWER ENSURE THAT THE PIPE WORK IS FULLY FLUSHED OUT 1 Unscrew the Red Cap and Washer from the shower outlet pipe and discard them in a suitable manner These have been used to seal the shower during transit and are no longer required 2 It is recommended that a WRAS Water Regulations Advisory Scheme listed isolating valve is fitted between the rising main and...

Page 9: ...ing Cable Sizes Fuse MCB Cable Length 4 0mm 6 0mm 32A Type B MCB 21m Max 35m Max 7 2 6 6kW 240 230V 6 0mm 10 0mm 40A Type B MCB 27m Max 45m Max 6 0mm 10 0mm 40A Type B MCB 27m Max 45m Max 8 5 7 8kW 240 230V 6 0mm 10 0mm 45A BS 1361 fuse 12m Max 21m Max 6 0mm 10 0mm 40A Type B MCB 27m Max 45m Max 9 5 8 7kW 240 230V 6 0mm 10 0mm 45A BS 1361 fuse 12m Max 21m Max Remember to upgrade the cable if it ru...

Page 10: ... can be selected and returns to the stop position g Check that inner knob B has been correctly aligned by turning clockwise and ensuring that knob turns approximately 3 4 of a turn 270 and when turned back fully anti clockwise returns to the high position 6 Replace the top and bottom fastening screws 7 Fit the shower hose and operate the shower first without the handset to flush out particles fit ...

Page 11: ...t No 83595319 Solenoid Valve Cat No 93597868 Chrome Curved Accessories Cat No 83595320 Neon Cable Assy Cat No 93590506 Curtain and Rail Pack Cat No 83792812 Tank Clip Cat No 93590715 Curtain and Rail Pack with PRV Washer Cat No 93795817 Non Slip Mat Cat No 83792811 Cylinder O Ring Cat No 93795809 Thermal Cut Out 50 88 C Cat No 93597871 Handset Cat No 93597860 Height Adjuster Cat No 93597861 ADDITI...

Page 12: ...oler Turn clockwise follow red arrows for warmer 4 When you have finished showering turn outer knob A anti clockwise to the position You have no need to adjust inner knob B 5 Water will continue to flow for up to 3 seconds before switching off This reduces the temperature of the water in the tank for the next user The neon indicator light will go out 6 Switch off the electricity supply at the ceil...

Page 13: ...E YOUNG ELDERLY AND THE INFIRM WHILST THEY USE THIS APPLIANCE The position of inner knob B will be approximately the same each time the shower is used varying only with incoming water temperature or pressure changes e g you will only need to change from summer to winter During normal operation if an overheated water temperature is sensed then the heater will switch off and the neon indicator will ...

Reviews: