General Product Operation......................................................................2

Spares Diagram and List.........................................................................3

Unit Dimensions.......................................................................................3

Problem Solving......................................................................................4

Tank Access............................................................................................5

Parts Replacement Guide.......................................................................5 - 6

Intentionally Blank..................................................................................7

AEP Address............................................................................................8

Page 2 of 8

Redring SB

The General Operational Process

1. After fixing to wall and checking all connections, turn on power and water
together.

2.The solenoid valve will now open and fill the tank until it reaches the low water
level sensor.

3. When the low water level sensor is contacted, the filling process stops and the
heating cycle starts, the heating will continue until the water reaches
approximately 98-99ºC.

4. Once this temperature is reached the heating stops and filling restarts, this
process of heat/fill/heat/fill continues until the top water level sensor is reached.
When water makes contact with the high water level sensor, the PCB isolates the
filling cycle from this function, and the element controlled by the PCB remains in
circuit to monitor for any heat top up’s that may be required.

5. If any subsequent water is used and the unit drops away from the high level
water sensor, the heat/fill/heat /fill process restarts until water is back at the high
level water sensor and at maximum temperature.

Summary of Contents for 1070800E

Page 1: ...Trouble Shooting All Models Redring SB Redring SB Professional On Wall Boiling Water Heater Models 1070800E 2 5 ltr 1070810E 5 ltr 1070815E 7 5 ltr 1070820E 10 ltr 1070825E 15 ltr 1070830E 20 ltr 1070...

Page 2: ...and the heating cycle starts the heating will continue until the water reaches approximately 98 99 C 4 Once this temperature is reached the heating stops and filling restarts this process of heat fil...

Page 3: ...311045 Control Board Assembly 2 5 Litre 15b 1311042 Control Board Assembly 5 to 25 Litre 16 1311058 Tap Cup Seal 17 1311060 Tap Insert 18 1310732 Tap Spring 399 0 399 0 399 0 6 2 1 8 6 2 1 8 6 2 1 8 6...

Page 4: ...ce thermistor steam sensor No 4 page 3 2 If above does not solve problem replace PCB No 15a or 15b page 3 3 Check the thermistor is positioned correctly Manual reset thermostat Unscrew 1 Check water s...

Page 5: ...e tank then the 3 nuts securing the element 2 at the bottom and 1 on the side of tank 5 Remove the element through the top opening 6 Replacement is the reverse procedure 7 Refit case and return to ope...

Page 6: ...bove in Cover Removal 2 Remove PCB cover plate 3 Remove the thermistor 4 The probe end of the thermistor pushes into the condensor tube so that the tip just covers the hole drilled in the condensor tu...

Page 7: ...Page 7 of 8 Redring SB Notes...

Page 8: ...cts Ltd Morley Way Peterborough PE2 9JJ England General enquiry Tel 44 0 1733 456789 Fax 44 0 1733 310606 Technical Hotline Tel 44 0 8709 000430 Fax 44 0 8709 000530 Sales Spares Tel 44 0 8709 000420...