RedPlate TruVerb Standard Operations Guide 

 

 

producing increased low end at louder volumes. The control clicks off when rotated to zero for no 
presence. 

Master Volume

 

– This is an active control and actually adds gain at the higher settings. The 

cleanest tones are achieved at settings below 7. 

 

REAR PANEL SECTION 

 

 

 
 
IEC Module

 

– contains the main power switch, power cord inlet connector and the fuse drawer 

which doubles as the voltage selector on export models. To access the fuse(s) use a small flat 
blade screwdriver in the notch at the bottom of the power cord inlet connector, the drawer snaps 
out in a rearward direction. The TruVerb can accept both the larger (3AG footprint) or smaller 
European (5mm X 20mm) fuses. A time delay variety (SLO-BLO) is recommended. 

The fuse 

drawer can be rotated on the export model (not shown) for voltage selection, make sure the correct 
value fuse (as listed on the rear panel) is located on the same side of the fuse drawer as the 
desired selection arrow. Line up the appropriate arrow on the fuse drawer with the arrow on the 
bottom right of the module for the proper VAC selection. 

 

Standby Switch

 

– This switch allows the tubes to warm up before operating the amplifier. Wait 

1 minute after power on to move it up to the operate position. For improved tube life and 
performance do not leave the amplifier in Standby position for longer than 20 minutes (better to just 
leave it in operate mode during performance intermissions).  

 
Bias adjustment and bias test point

 

– Allows external access for bias adjustment (see bias 

procedure in the 

Maintenance

 section). 

 
LINE OUT

 

– A line level signal jack derived from the speaker output which contains the whole 

tone of the amplifier. 

 

Speaker Jacks

 

– The MAIN and EXT jacks are wired in parallel. The MAIN jack must be used 

first because it has a protection device. ALWAYS HAVE A SPEAKER CONNECTED TO AVOID 
PERMANENT AMPLIFIER AND OUTPUT TUBE DAMAGE. 

 

Impedance Selector Ω

 - Set this to the total impedance of all attached speakers.  

 

SEND and RETURN Jacks

 

– The send jack connects to the input of an external effects device 

and the return jack connects to the output of an external effects device. The return jack interrupts 
the signal path so the external effects unit must mix the wet and dry signals. 

 

 

POWER ON/OFF PROCEDURE 

1.  Check the Standby switch to make sure it is toggled downward for Standby.  
2.  Toggle the main power switch to the up position (this switch is located at the top of the IEC 

input module). The front panel pilot light should be lit. 

3.  Wait one minute and then toggle the Standby switch upwards to the Operate position. 

Summary of Contents for TruVerb Standard

Page 1: ...ase take a moment and review this manual for an understanding of all the available features or just put all the knobs at noon and play This Manual applies to TruVerb models produced after 06 01 2011 See the Addendum Section for newer TruVerb model differences Signal Path Block Diagram FRONT PANEL Input Jack Typical High impedance input to the amplifier Designed to be Pedal Friendly ...

Page 2: ...cy and achieves maximum fat midrange by engaging a mid boost in position 6 Middle Control Controls the amount of Midrange frequencies somewhat interactive with the Bass Control Pulls to enable Deep which scoops some midrange frequencies and emphasizes Bass makes your electric sound more like an acoustic Lows Selector A four position rotary switch it steps through 4 progressively fatter positions o...

Page 3: ...er Wait 1 minute after power on to move it up to the operate position For improved tube life and performance do not leave the amplifier in Standby position for longer than 20 minutes better to just leave it in operate mode during performance intermissions Bias adjustment and bias test point Allows external access for bias adjustment see bias procedure in the Maintenance section LINE OUT A line lev...

Page 4: ...g No user serviceable parts inside so unless you know what you re doing please refer to a qualified service person only BIAS PROCEDURE See Addendum for TruVerb88 bias procedure 1 When new 6L6 GC output tubes are installed it is important to re bias the amp for optimal performance No biasing needed for 6V6 tubes because they can only be used in cathode bias position 2 ALWAYS HAVE A SPEAKER CONNECTE...

Page 5: ...age for 3 years from the original manufacture date please inform us of an ownership change to insure coverage The actual electrical components in your amplifier are warranted for a period of 3 years Exclusions are vacuum tubes reverb tanks cables speakers and cosmetics which are warranted for 30 days Improper handling or product misuse or product abuse or unauthorized repair work or unauthorized m...

Reviews: