US-16
EBZ7150/RH
BEFORE STORING THE BLOWER:
1. Drain a fuel tank and push the primer
bulb until it becomes empty of fuel.
2 .Remove the spark plug and drop a
spoonful of 2-cycle oil into the cylider.
Crank the engine several time and
install the spark plug.
3. Store unit in a dry, dust free place, out
of the reach of children.
10. Storage
11. Disposal
• When disposing your machine, fuel or
oil for the machine, be sure to allow
your local regulations.
Case 1. Starting failure
CHECK
PROBABLE CAUSES
ACTION
fuel tank
➞
incorrect fuel
➞
drain it and with correct fuel
fuel filter
➞
fuel filter is clogged
➞
clean
carburetor adjustment screw
➞
out of normal range
➞
adjust to normal range
sparking (no spark)
➞
spark plug is fouled/wet
➞
clean/dry
➞
plug gap is incorrect
➞
correct (GAP: 0.6 – 0.7 mm)
spark plug
➞
disconnected
➞
retighten
Case 2. Engine starts but does not keep running/Hard re-starting.
CHECK
PROBABLE CAUSES
ACTION
fuel tank
➞
incorrect fuel or staled fuel
➞
drain it and with correct fuel
carburetor adjustment screw
➞
out of normal range
➞
adjust to normal range
muffler,cylinder (exhaust port)
➞
carbon is built-up
➞
wipe away
air cleaner
➞
clogged with dust
➞
wash
cylinder fin, fan cover
➞
clogged with dust
➞
clean
When your unit seems to need further service, please consult with our service shop in your area.
12. Troubleshooting guide