![RedMax 967685301 Operator'S Manual Download Page 15](http://html1.mh-extra.com/html/redmax/967685301/967685301_operators-manual_1429629015.webp)
Troubleshooting
Keypad
LED display
Possible faults
Possible action
Green activate LED flashing
Low battery voltage.
Charge the battery.
Red error LED flashing
Overload.
The cutting attachment is jammed. deacti-
vate the product. Remove the battery. Clean
the cutting attachment from unwanted mate-
rials.
Temperature deviation.
Let the product cool down.
The power trigger and the acti-
vate button are pressed at the
same time.
Release the power trigger and the product is
active.
The product does not start
Dirt in the battery connectors.
Clean the battery connectors with com-
pressed air or a soft brush.
Error LED is lit with red light
The product needs servicing.
Contact your servicing agent.
Battery
LED display
Possible faults
Possible action
Green activate LED flashing
Low battery voltage.
Charge the battery.
Error LED flashing
Temperature deviation.
Use the battery in surroundings where tem-
peratures are between -10°C (14°F) and
40°C (104°F).
Over voltage.
Check that the mains voltage corresponds
with that stated on the rating plate on the
product.
Remove the battery from the battery charger.
Error LED is lit
Cell difference is to much (1V).
Contact your servicing agent.
463 - 002 - 09.01.2018
15