3.4
Status Screens
3.4.1
General Information
The General Information screen displays system and the Ethernet interface details.
Fig. 19: Web - General Information Screen
System
System Name
: Operator assigned name identifying this unit.
System Details
: Additional operator-entered details describing this unit.
System Location
: Information about the location of this unit.
Contact
: Operator-entered contact information for this unit.
System S/N
: Serial number of this unit. Also identifies the unit type.
Radio Type
: Type of radio installed.
Radio Type
Frequency Range (MHz)*
T072x
470 -
698
T212x
2100 - 2300
T202x
2300 - 2800
T352x
3300 - 3800
T502x
4940 - 5875
* Range is restricted by regional regulations (options key).
System Mode
: The system modes are enabled by the active options key.
The operator
MUST
reboot the RDL-3000 after making changes to this parameter.
PMP SC
: This unit is configured as a sector controller. The unit automatically begins
transmitting poll messages to locate and register remote subscribers.
PMP SS
: This unit is configured to operate as a subscriber. The unit monitors the
selected RF channel(s) for poll messages from a sector controller.
SC ID
: (SC only)
Unique identification number of this sector controller.
Software Version
:
Firmware version in use.