SU-O
Quick Install Guide
70-00067-01-02
Proprietary Redline Comm. © 2010
Page 6 of 12
October 9, 2008
Important Notice: Outdoor Cable Assembly
Redline does not endorse or support the use of outdoor cable assemblies: i) not
supplied by Redline, ii) third-party products that do not meet Redline's cable and
connector assembly specifications, or iii) cables not installed and
weatherproofed as specified in this manual. Refer to the Redline Limited
Standard Warranty and RedCare service agreements.
Figure 3: Outdoor Ethernet Cable - SU-O Cable Connection
The weatherproof connector must be finger-tight plus 1/16th turn
only. Choose a tool suitable to avoid damaging the plastic connector.
The minimum diameter to pass the outdoor connector through a
conduit or hole is 26 mm (1 in).
3.4 Connect the SU-O to the PoE Adapter
The indoor end of this cable is terminated with a standard indoor RJ-
45 connector for connection to the indoor PoE adapter. The SU-O
Ethernet cable must be connected to the PoE port marked 'DATA
AND POWER OUT'.
Figure 4: SU-O PoE Connection: DATA & POWER OUT
The minimum diameter to pass the indoor connector through a
conduit or hole is 18 mm (11/16 in).