User
AN-80i
Manual
70-00072-01-07
Proprietary Redline Communications © 2010
Page 89 of 106
Sept 18, 2008
6.4.2
PMP Status Codes
The PMP status code is displayed in a series of hexadecimal characters representing
the status of different alarm conditions. The value '1' indicates the associated condition
is active. All unused bits are set to zero.
To determine the status, the hexadecimal number must be converted to binary notation.
It is recommended to use a scientific calculator that supports binary notation (i.e.,
Windows on-screen calculator). Set the mode for Hex and enter the status code.
Change the mode to binary and match active bits (1) to the PMP Status Codes table.
For example, if 'Radio Over Temperature' bit 1 and 'PLL Error' bit 4 were active, the
status code value would be Hex '12' (binary 1 0010).
Table 47
:
Diag. - PMP Status Code Bits
31 30 29 28 27 26 25 24 23 22 21 20 19 18 17 16 15 14 13 12 11 9 8 7 6 5 4 3 2 1 0
Table 48
:
Diag. - PMP Status Codes
Bit
Description
1
Radio over-temperature
4, 5, 6
PLL Errors
8
Firmware Error
16
No Ethernet packets received by the wireless MAC
17, 18, 19, 20,
21, 22, 23, 24,
25, 26, 27, 28
MAC Internal Errors