- 16 -
DS3100
External oil supply
#
Changing oil in the plug-on pump (after every 100 operating hours)
- Unscrew the bleed screw (1).
- Loosen the drain screw (2) below and discharge the oil.
- Screw in the filler screw with a new gasket.
- Turn the gear unit 180 degrees.
- Fill only with
SAE85-W140
oil up to the height of the sight glass (3).
- Screw in the drain screw (2) with a new gasket.
Used oil is a threat to the environment; dispose of it in
accordance with the environmental regulations.
Fig. 9: External oil supply
Changing oil in hydraulic tank (as required)
- Unscrew the filler neck (6).
- Loosen the suction hose (4) and drain the oil.
- Screw the suction hose on again.
- Fill in
Plantosyn 3268 ECO
up to the middle of the hose (5).
- Screw in the filler neck (6) again.
It is a closed hydraulic circuit. Nevertheless, to exclude possible impurities,
the return flow filter (7) must be replaced after every 100 operating hours.
Used oil is a threat to the environment; dispose of it in
accordance with the environmental regulations.
3
5
2
4
1
6
7