![REDEKOP Case IH AFX 7230 Series Manual For Installation Download Page 18](http://html1.mh-extra.com/html/redekop/case-ih-afx-7230-series/case-ih-afx-7230-series_manual-for-installation_1429048018.webp)
18
4.1 Hydraulic Hoses Disconnect
4.1.1
Remove steel hydraulic line (
A
) x2 from hydraulic
block (
C
)
- hoses will leak upon removal, place a pail below to
catch any fluids
4.1.2
Hold steel lines up to prevent oil from leaking
4 Straw Spreader Removal
B
B
D
A
A
A
C
HYDRAULIC LINES MAY BE
UNDER PRESSURE
Escaping fluid under pressure can penetrate the skin
causing serious injury.
Avoid the hazard by relieving pressure before
disconnecting hydraulic or other lines.
Tighten all connections before applying pressure.
E
C
4.1.3
Install Hydraulic Port Caps H14-12F (
E
) onto ports
of hydraulic block (
C
) where the steel hydraulic lines (
A
)
were just removed from
C
Ensure that the
Hydraulic Cap Fittings have
been tightened
- if removing prior to kit arrival - purchase these 2 fittings
in order to drive combine
(CNH Part # 9840575)