background image

www.sureheat.com

23

200041-01B

TROUBLESHOOTING

Problem

Possible Cause

Corrective Action

Slight  smoke  or  odor 

during initial operation.

1. Residues from manufactur-

ing process.

1. Problem will stop after a few 

hours of operation.

Heater produces a whis-

tling noise when burner 

is lit.

1. Turning control knob to high 

(5) position when burner is 

cold.

2. Air in gas line.

3. Air passageways on heater 

are blocked.

4. Dirty  or  partially  clogged 

burner orifice.

1. Turn control knob to low (1) 

position and let warm up for 

a minute.

2. Operate  burner  until  air  is 

removed from line. Have gas 

line  checked  by  local  gas 

supplier.

3  Observe  minimum  installa-

tion  clearances  (Figure  4, 

page 9).

4  Clean burner (see 

Care and 

Maintenance

,  page  20)  or 

replace burner orifice.

Heater produces a click-

ing/ticking noise just after 

burner is lit or shut off.

1. Metal  is  expanding  while 

heating or contracting while 

cooling.

1. This  is  common  with  most 

heaters.  If  noise  is  exces-

sive,  contact  qualified  ser-

vice technician.

White  powder  residue 

forming  within  burner 

box or on adjacent walls 

or furniture.

1. When  heated,  the  vapors 

from  furniture  polish,  wax, 

carpet  cleaners,  etc.,  turn 

into white powder residue.

1. Turn heater off when using 

furniture polish, wax, carpet 

cleaner or similar products.

Heater  produces  un-

wanted odors.

1. Heater is burning vapors from 

paint, hair spray, glues, etc. 

See IMPORTANT statement, 

page 21.

2. Gas leak. See 

Warning State-

ment

 at the top of page 21.

3. Low fuel supply (propane/LP 

gas only).

1. Ventilate  room.  Stop  using 

odor causing products while 

heater is running.

2. Locate and correct all leaks 

(see 

Checking Gas Connec-

tions

, page 15).

3. Refill supply tank (Propane/

LP models).

Heater  shuts  off  in  use 

(ODS operates).

1. Not enough fresh air is avail-

able.

2. Low line pressure.

3. ODS/pilot  is  partially 

clogged.

1. Open window and/or door for 

ventilation.

2. Contact local gas supplier.

3. Clean  ODS/pilot  (see 

Care 

and Maintenance

, page 20).

Gas  odor  exists  even 

when control knob is in 

OFF position.

1. Gas  leak.  See 

Warning 

Statement

 at top of page 21.

2. Control valve is defective.

1. Locate and correct all leaks 

(see 

Checking Gas Connec-

tions

, page 15).

2. Replace control valve.

Moisture/condensation 

noticed on windows.

1. Not  enough  combustion/

ventilation air.

1. Refer  to 

Air for Combus-

tion and Ventilation

 require-

ments, page 7.

Summary of Contents for IWH10NLTC

Page 1: ...pliance Do not touch any electrical switch do not use any phone in your building Immediately call your gas supplier from a neighbor s phone Follow the gas supplier s instructions If you cannot reach y...

Page 2: ...nce may be installed in an aftermarket per manently located manufactured mobile home where not prohibited by local codes This appliance is only for use with propane or natural gas This appliance is eq...

Page 3: ...air at once Have heater serviced Some people are more af fected by carbon monoxide than others These include pregnant women people with heart or lung disease or anemia those under the influ ence of a...

Page 4: ...ocked positions Poor combustion and higher levels of carbon monoxide may result 9 Do not use heater if any part has been under water Immediately call a qualified service technician to inspect the room...

Page 5: ...l gas by having your quali fied installer follow the instructions on page 11 and the markings on the heater PIEZO IGNITION SYSTEM This heater is equipped with a piezo ignitor this system requires no m...

Page 6: ...product of gas combus tion An unvented room heater produces ap proximately one 1 ounce 30 mL of water for every 1 000 BTUs 0 3 KWs of gas input per hour Unventedroomheatersarerecommended as supplement...

Page 7: ...s This will insure proper venting of vented fuel burning appliances WARNING This heater shall not be installed in a room or space unless the required vol ume of indoor combustion air is provided by th...

Page 8: ...ings for inlet or outlet air into attic if attic has a thermostat controlled power vent Heated air entering the attic will activate the power vent Rework worksheet adding the space of the adjoining un...

Page 9: ...s Viewed From Front of Heater CAUTION This heater cre ates warm air currents These currents move heat to wall sur faces next to heater Installing heater next to vinyl or cloth wall coverings or operat...

Page 10: ...e of installa tion could damage this appliance and render it inoperable The installer shall replace the access cover before completing the installation and operat ing this appliance GAS SELECTION For...

Page 11: ...as supply to propane supply 1 Remove 2 screws from cover plate located on back of heater to expose fuel selection device see Figure 6 2 For propane gas press in knob using a flat screwdriver with a bl...

Page 12: ...ing bracket onto wall Line up last hole on each end of bracket with holes drilled in wall 3 Insert mounting screws through bracket and into wall studs 4 Tighten screws until mounting bracket is firmly...

Page 13: ...Place heater on wall mounting bracket 3 Mark screw locations on wall INSTALLATION Figure 12 Mounting Heater Onto Mounting Bracket Mounting Bracket attached to wall Horizontal Slots Stand Out Tab Figu...

Page 14: ...ter to gas line Gas line pressure must be no greater than 10 5 of water If gaslinepressureishigher heater regulator damage could occur CAUTION Avoid damage to regulator Hold gas regulator with wrench...

Page 15: ...going into pipe Excess sealant in pipe could result in clogged heater valves For propane LP gas the installer must supply an external regulator The external regulator will reduce incoming gas pressur...

Page 16: ...quipment Shutoff Valve Figure 17 Natural Gas Supply Gas Meter Gas Valve Equipment Shutoff Valve PRESSURE TESTING HEATER GAS CONNECTIONS 1 Open equipment shutoff valve see Fig ure 16 2 For natural gas...

Page 17: ...Until repairs are made light pilot with match To light pilot with match see Manual Lighting Procedure page 18 7 Keep control knob pressed in for 30 seconds after lighting pilot After 30 seconds releas...

Page 18: ...in 8 Turn control knob counterclockwise to desired heating level The main burner should light Set control knob to any heat level between 1 and 5 CAUTION Do not try to ad just heating levels by using t...

Page 19: ...burner flame pattern often Incorrect flame patterns indicate the need for cleaning see Care and Maintenance page 20 or service WARNING Only a qualified service person should service and repair heater...

Page 20: ...PSl Your local computer store hardware store or home center may carry compressed air in a can You can use a vacuum cleaner in the blow position If using compressed air in a can please follow the dire...

Page 21: ...s no spark at ODS pilot 1 Ignitor electrode is posi tioned wrong Ignitor elec trode is broken 2 Ignitor electrode is not con nected to ignitor cable 3 Ignitor cable is pinched or wet 4 Broken ignitor...

Page 22: ...t 1 Burner orifice is clogged 2 Burner orifice diameter is too small 3 Inlet gas pressure is too low 1 Clean burner orifice see Care and Maintenance page 20 or replace burner orifice 2 Replace burner...

Page 23: ...alls or furniture 1 When heated the vapors from furniture polish wax carpet cleaners etc turn into white powder residue 1 Turn heater off when using furniture polish wax carpet cleaner or similar prod...

Page 24: ...oning Type of gas used Propane LP or Natural gas NG Purchase date ACCESSORIES Purchase these heater accessories from your local dealer If they can not supply these acces sories contact SHM Internation...

Page 25: ...heat propane LP gas supply might be low propane LP units only You may feel your gas pressure is too low If so contact your local gas supplier TECHNICAL SERVICE You may have further questions about ins...

Page 26: ...www sureheat com 200041 01B 26 PARTS MODEL IWH10NLTC 16 1 2 3 4 15 12 7 6 8 1 8 2 5 14 17 13 11 9 10...

Page 27: ...03 Lower Front Panel 1 5 DFPB 2B MB Burner Can Assembly 1 6 PF MED ODS Bracket 1 7 NDD0308 800 1 ODS Pilot 1 8 1 ML090 03N Injector Inner 1 8 2 ML090 03L Injector Outer 1 9 LHY P 300 Gas Selector Valv...

Page 28: ...www sureheat com 200041 01B 28 PARTS MODEL IWH16NLTC 18 17 16 1 2 3 4 15 12 7 6 8 1 8 2 5 14 13 19 11 9 10...

Page 29: ...B 3B Burner Can Assembly 1 6 PF MED ODS Bracket 1 7 NDD0308 800 1 ODS Pilot 1 8 1 ML090 02L Injector Inner 1 8 2 ML090 02N Injector Outer 1 9 LHY P 300 Gas Selector Valve Assembly 1 10 ML029 01 Main V...

Page 30: ...www sureheat com 200041 01B 30 PARTS MODEL IWH26NLTC 18 17 16 1 2 3 4 15 12 7 6 8 1 8 2 5 14 13 19 11 9 10...

Page 31: ...5B MB Burner Can Assembly 1 6 PF MED ODS Bracket 1 7 NDD0308 800 1 ODS Pilot 1 8 1 ML090 01L Injector Inner 1 8 2 ML090 01N Injector Outer 1 9 LHY P 300 Gas Selector Valve Assembly 1 10 ML029 01 Main...

Page 32: ...age resulting from any of the following Negligent use or misuse of the product including exposing the product to chemicals or cleaning products not approved by SHM International Corp Corrosion rust or...

Page 33: ...No toque ning n interruptor el ctrico no use ning n tel fono en el edificio Llame inmediatamente a su proveedor de gas desde el tel fono de alg n vecino Siga las instrucciones del proveedor de gas Si...

Page 34: ...en una casa m vil con ubicaci n permanente y adquirida en el mercado de posventa siempre que no est prohibido por los c digos locales Este dispositivo es s lo para su uso con propano o gas natural Es...

Page 35: ...eza mareos y o n usea Si usted presenta estos s ntomas es posible que el calentador no est funcio nando correctamente Respire aire fresco inmediatamente Haga que le den servicio al calentador El mon x...

Page 36: ...ntador se apaga no lo vuelva a encender hasta que se le haya pro porcionado aire fresco del exterior Si el calentador continua apagando se debera ser revisado por personal calificado 6 No haga funcion...

Page 37: ...ncho x profundidad 19 1 8 14 1 8 7 1 8 23 1 2 19 1 4 8 3 4 23 1 2 x 26 5 8 x 8 3 4 Dimensiones caja alto x ancho x profundidad 22 16 3 4 8 7 8 25 3 4 21 3 4 10 25 3 4 x 28 1 2 x 10 Pesa de calentador...

Page 38: ...CONTROL TERMOST TICO Modelos termostato s lo El control apaga y enciende el quemador de forma autom tica por ciclos para mantener una temperatura ambiente deseada NORMAS LOCALES Instale y use el cale...

Page 39: ...sin ventilaci n produce aproxima damente 29 57 ml 1 onza de agua por cada 1 000 BTU 0 29 kW de entrada de gas por hora Los calentadores de habitaci n sin ven tilaci n son recomendables como calefacci...

Page 40: ...su funcionamiento Usted debe proporcionar la cantidad adecuada de aire fresco para estos aparatos Esto asegura que la ventilaci n de los aparatos que queman combustible sea la adecuada ADVERTENCIA Est...

Page 41: ...ura 3 Aire del exterior para ventilaci n Proporcione aire fresco adicional mediante el uso de rejillas o conductos de ventilaci n Debe haber dos aberturas permanentes una a 30 48 cm 12 del techo y otr...

Page 42: ...cortinas muebles ropa u otros objetos inflamables est namenosde0 914m 36 del frente de la parte superior o laterales del calentador en reas de mucho tr fico en reas con mucho viento o con corrientes f...

Page 43: ...xi n a gas propano LP S lo un t c nico calificado o un t cnico en mantenimiento pueden realizar laselecci ndelgasylaconexi n al suministro de gas PRECAUCI N Se proh be instalar dos l neas de gas al mi...

Page 44: ...re los 2 tornillos de la placa de la cubierta situados en la parte posterior del calentador para exponer dispositivo de selecci n de combustible consulte la Figura 5 2 Para GAS NATURAL presione la per...

Page 45: ...gura 4 p gina 43 Si puede proporcione dis tancias m nimas mayores con respecto al piso y la pared de uni n 2 Marque la ubicaci n de los tornillos en la pared consulte la figura 9 p gina 46 Nota Marque...

Page 46: ...de pared 6 Inserte los tornillos de montaje en el so porte y en los anclajes de pared 7 Apriete los tornillos hasta que el soporte de montaje est asegurado firmemente a la pared INSTALACI N 17 cm 6 3...

Page 47: ...ontaje inferiores 3 Marque la ubicaci n de los tornillos en la pared 4 Quite el calentador del soporte de montaje 5 Si va a instalar los tornillos de montaje inferiores en una pared hueca o s lida ins...

Page 48: ...calentador sea el adecuado Si la tuber a es demasiado angosta se pro ducir una p rdida indebida de presi n PRECAUCI N Para gas propano LP nunca conecte el calentadordirectamentealsumi nistro de gas p...

Page 49: ...po es para abrir o cerrar el suministro de gas al aparato Para gas propano LP aplique una peque a cantidad de sellador de tuber a a las roscas NPT macho Esto evitar que el exceso de sellador entre a l...

Page 50: ...e gas natural o cerca de ste o bien usando aire comprimido 4 Revise todas las uniones del sistema de tuber a de suministro de gas Aplique en todas las uniones alg n l quido de detec ci n de fugas que...

Page 51: ...ENCIA No seguir estas instrucciones al pie de la letra puede resultar en incen dio o explosi n que produzcan da os a la propiedad lesiones f sicas o la muerte A Este aparato tiene un piloto que se deb...

Page 52: ...o encender el piloto El piloto est instalado en la parte anterior del quemador El piloto puede ser visto a trav s de la parrilla En caso ne cesario contin e oprimiendo el bot n de encendido hasta que...

Page 53: ...e gas natural Quemador de gas propano LP Termopar Electrodo del encendedor Entrada de aire al piloto Entrada de aire al piloto FUNCIONAMIENTO DEL CONTROL CON TERMOSTATO C MO CERRAR EL SUMINISTRO DE GA...

Page 54: ...or Patrones de llama incorrectos indican la necesidad de limpieza o servicio de mantenimiento consulte Cuidado y mantenimiento p gina 55 ADVERTENCIA S lo una persona de servicio capacitada debe repara...

Page 55: ...entador limpio y libre de polvo y suciedad Para limpiar estas piezas se recomienda usar aire comprimido a una presi n no mayor de 30 PSI Es posible que la tienda local de equipo de c mputo ferreter a...

Page 56: ...toque ning n interruptor el ctrico no use ning n tel fono en el edificio Llame inmediatamente a su proveedor de gas desde el tel fono de alg n vecino Siga las instrucciones del proveedor de gas Si no...

Page 57: ...LOTO 7 Comun quese con la compa a local de gas propano LP El piloto ODS se en ciende pero la llama se extinguecuandolaperilla de control se suelta 1 La perilla de control no est presionada completamen...

Page 58: ...as est defectuoso 1 Limpie el quemador consulte Cuidado y mantenimiento en la p gina 55 o remplace el orificio del quemador 2 Remplace el quemador 3 Remplace el regulador de gas Llamas amarillas alta...

Page 59: ...contraen al enfriarse 1 Esto es normal en la mayor a de los calentadores Si el ruido es excesivo comun quese con una persona de servicio capacitada Se forma un residuo de polvoblancodentrodela caja d...

Page 60: ...as ventanas 1 No hay suficiente aire para combusti n o ventilaci n 1 Consulte los requisitos de Aire Para Combusti n y Ventila ci n p gina 40 SOLUCI N DE PROBLEMAS PIEZAS DE REPUESTO Nota use s lo pie...

Page 61: ...n del gas de entrada sea muy baja El piloto no permanecer encendido El quemador tendr un retraso durante el encendido El calentador no producir el calor especificado El suministro de gas propano LP p...

Page 62: ...www sureheat com 200041 01B 62 PIEZAS MODELO IWH10NLTC 16 1 2 3 4 15 12 7 6 8 1 8 2 5 14 17 13 11 9 10...

Page 63: ...panel frontal 1 5 DFPB 2B MB Asamblea de grabadora 1 6 PF MED Soporte ODS 1 7 NDD0308 800 1 Piloto ODS 1 8 1 ML090 03N Inyector interior 1 8 2 ML090 03L Inyector exterior 1 9 LHY P 300 Conjunto de la...

Page 64: ...www sureheat com 200041 01B 64 PIEZAS MODELO IWH16NLTC 18 17 16 1 2 3 4 15 12 7 6 8 1 8 2 5 14 13 19 11 9 10...

Page 65: ...ea de grabadora 1 6 PF MED Soporte ODS 1 7 NDD0308 800 1 Piloto ODS 1 8 1 ML090 02L Inyector interior 1 8 2 ML090 02N Inyector exterior 1 9 LHY P 300 Conjunto de la v lvula de gas selector 1 10 ML029...

Page 66: ...www sureheat com 200041 01B 66 PIEZAS MODELO IWH26NLTC 18 17 16 1 2 3 4 15 12 7 6 8 1 8 2 5 14 13 19 11 9 10...

Page 67: ...blea de grabadora 1 6 PF MED Soporte ODS 1 7 NDD0308 800 1 Piloto ODS 1 8 1 ML090 01L Inyector interior 1 8 2 ML090 01N Inyector exterior 1 9 LHY P 300 Conjunto de la v lvula de gas selector 1 10 ML02...

Page 68: ...tancias qu micas o productos de limpieza no aprobados por SHM International Corp Corrosi n oxidaci n o des coloraci n de cualquier tipo Uso o instalaci n contrarios a las instrucciones especificadas y...

Reviews: