background image

www.sureheat.com

200311-01C

18

IGNIT

OR

OFF

LOW

PILOT/ IGN

OPERATION

FOR YOUR SAFETY READ BEFORE LIGHTING

 WARNING: If you do not fol-

low these instructions exactly, a 

fire or  explosion may result caus-

ing property damage, personal 

injury or loss of life.

A.  This appliance has a pilot which must 

be lighted by hand. When lighting the 

pilot, follow these instructions exactly.

B.  BEFORE  LIGHTING  smell  all  around 

the appliance area for gas. Be sure to 

smell next to the floor because some 

gas is heavier than air and will settle 

on the floor.

 

WHAT TO DO IF YOU SMELL GAS

• Do not try to light any appliance.

• Do not touch any electric switch; do 

not use any phone in your building.

• Immediately  call  your  gas  supplier 

from a neighbor’s phone. Follow the 

gas supplier’s instructions.

• If you cannot reach your gas supplier, 

call the fire department.

C.  Use only your hand to push in or turn 

the gas control knob. Never use tools. 

If  the  knob  will  not  push  in  or  turn 

by  hand,  don’t  try  to  repair  it,  call  a 

qualified service technician. Force or 

attempted repair may result in a fire or 

explosion.

D.  Do not use this appliance if any part 

has been under water. Immediately call 

a qualified service technician to inspect 

the appliance and to replace any part of 

the control system and any gas control 

which has been under water.

1.  STOP!  Read  the  safety  information  on 

above.

2.  Check that gas supply to heater is on.
3.  Push in gas control knob slightly and turn 

clockwise 

 to the OFF position.

Note: Knob cannot be turned from PILOT to 

OFF unless knob is pushed in slightly. Do 

not force.

4.  Wait five (5) minutes to clear out any air. 

Then  smell  for  gas,  including  near  the 

floor. If you smell gas, STOP! Follow "B" 

in the safety information above. If you do 

not smell gas, go to the next step.

5.  Push in gas control knob slightly and turn 

counterclockwise 

 to "PILOT/IGN" 

and press for five (5) seconds

 

Note:  The  first  time  that  the  heater  is 

operated after connecting the gas supply, 

the control knob should be pressed for 

about thirty (30) seconds. This will allow 

air to bleed from the gas system. If pilot 

does not stay lit, refer to Troubleshooting, 

pages 22 though 25. Also contact a quali-

fied service technician or gas supplier for 

repairs. Until repairs are made, light pilot 

with match.

LIGHTING INSTRUCTIONS

• If  control  knob  does  not  pop  up  when 

released,  contact  a  qualified  service 

technician or gas supplier for repairs.

6.  With control knob pressed in, push down 

and  release  the  ignitor  button. This  will 

light pilot. If needed, keep pressing ignitor 

button until pilot lights. 

Note: If pilot does 

not stay lit, refer to Troubleshooting, pages 

22  though  25. Also  contact  a  qualified 

service technician or gas supplier for 

repairs. Until repairs are made, light pilot 

with match. To light pilot with match, see 

Manual Lighting Procedure

, page 19

.

Figure 20 - Control Knob in the OFF 

Position

Ignitor Button

Control 

Knob

Summary of Contents for BWH10NLMC-2

Page 1: ...ot touch any electrical switch do not use any phone in your building Immediately call your gas supplier from a neighbor s phone Follow the gas supplier s instructions If you cannot reach your gas supp...

Page 2: ...er installation adjustment al teration service or maintenance can cause injury or property damage Refer to this manual for correct in stallation and operational procedures For assistance or additional...

Page 3: ...er serviced Some people are more af fected by carbon monoxide than others These include pregnant women people with heart or lung disease or anemia those under the influ ence of alcohol and those at hi...

Page 4: ...t cleaner or similar products turn heater off If heated the vapors from these prod ucts may create a white powder residue within burner box or on adjacent walls or furniture 8 Do not use heater if any...

Page 5: ...quipped to operate on either Propane LP or Natural gas The heater is shipped from the factory ready for connect ing to Propane LP The heater can easily be changed to Natural gas by having your quali f...

Page 6: ...UCT OF UNVENTED ROOM HEATERS Water vapor is a by product of gas combus tion An unvented room heater produces ap proximately one 1 ounce 30 mL of water for every 1 000 BTUs 0 3 KWs of gas input per hou...

Page 7: ...eathe Fresh air must enter your home All fuel burning ap pliances need fresh air for proper combustion and ventilation Exhaust fans fireplaces clothes dryers and fuel burning appliances draw air from...

Page 8: ...to adjoining room see option 3 Figure 2 Follow the National Fuel Gas Code ANSI Z223 1 NFPA 54 Air for Combustion and Ventilation for required size of ventilation grills or ducts Ventilation Air From O...

Page 9: ...nces as Viewed From Front of Heater CAUTION This heater cre ates warm air currents These currents move heat to wall sur faces next to heater Installing heater next to vinyl or cloth wall coverings or...

Page 10: ...pro vides the strongest hold Insert mounting screws through mounting bracket and into wall studs 2 Attaching to wall anchor This method allows you to attach mounting bracket to hollow walls wall areas...

Page 11: ...NT Do not hammer anchor key For thick walls over 1 2 thick or solid walls do not pop open wings 5 Place mounting bracket onto wall Line up last hole on each end of bracket with wall anchors 6 Insert m...

Page 12: ...Do not replace front panel at this time Replace front panel after making gas connec tions and checking for leaks Figure 9 Mounting Heater Onto Mounting Bracket Mounting Bracket attached to wall Horizo...

Page 13: ...void gas leak age for the gas not being used at the inlet of regulator a qualified installer or service technician must use supplied cap You will notice a color coded plungerontheinsideoftheregu lator...

Page 14: ...ile pushing in rotate the fitting clockwise until the threads engage the regulator After the fitting has been hand tightened into the regulator use a wrench to complete tightening of the fitting Insta...

Page 15: ...the heater and gassupply Gassupplierprovides externalregulatorfornaturalgas Theinstallerprovidestheexternal regulator for propane LP gas CAUTION Avoid damage to regulator Hold gas regulator with wren...

Page 16: ...lator with Vent Pointing Down Propane LP Supply Tank Equipment Shutoff Valve Ground Joint Union 3 8 NPT Pipe Nipple Tee Joint Reducer Bushing to 1 8 NPT 1 8 NPT Plug Tap Test Gauge Connection Sediment...

Page 17: ...l leaks at once 6 Light heater see Lighting Instructions on page 18 Check all other internal joints for leaks 7 Turn off heater see To Turn Off Gas Ap pliance page 19 8 Replace front panel 1 Open equi...

Page 18: ...rmation on above 2 Check that gas supply to heater is on 3 Push in gas control knob slightly and turn clockwise to the OFF position Note Knob cannot be turned from PILOT to OFF unless knob is pushed i...

Page 19: ...re lighting pilot again 8 To select the desired heating level partially press down the control knob slightly and turn counterclockwise Release downward pressure on the knob while continuing to turn un...

Page 20: ...to cool which shuts the heater off If pilot flame pattern is incorrect as shown in Figure 23 turn heater off see To Turn Off Gas to Ap pliance page 19 see Troubleshooting pages 22 through 25 WARNING I...

Page 21: ...es 2 Remove four screws securing front panel 3 Pull front panel forward 4 Inspect burner and pilot for dust and dirt 5 Blow air through the ports slots and holes in the burner 6 Replace front panel us...

Page 22: ...as supply exceeds 9 5 WC the unit will not operate Either contact your gas sup plier to check and adjust the inlet pressure or a qualified service technician can bypass the pressure switch Before atte...

Page 23: ...ark at ODS pilot but no ignition 1 Gas supply is turned off or equipment shutoff valve is closed 2 Control knob not fully pressed in while pressing ignitor button 3 Air in gas lines when in stalled 4...

Page 24: ...1 Burner orifice is clogged 2 Inlet gas pressure is too low 1 Clean burner orifice see Care and Maintenance page 21 2 Contact local gas supplier Delayed ignition of burner s 1 Manifold pressure is too...

Page 25: ...oducts Heater produces un wanted odors 1 Heater is burning vapors from paint hair spray glues etc See IMPORTANTstatement page22 2 Gas leak See Warning State ment at the top of page 22 3 Low fuel suppl...

Page 26: ...www sureheat com 200311 01C 26 PARTS MODEL BWH10NLMC 2 2 11 3 17 9 8 7 1 16 10 5 6 14 13 15 4 12...

Page 27: ...racket 1 3 161133 01 Piezo Ignitor 1 4 161392 01 Manual Control Valve 1 5 Burner Assembly 1 6 161139 02 ODS Pilot 1 7 Safety Dual Fuel Regulator 1 8 161200 01 Inlet Cover Plug 1 9 160960 01 Cap with S...

Page 28: ...lling Customer Service or your dealer have ready Your name Your address Model and serial number of your heater How heater was malfunctioning Type of gas used Propane LP or Natural gas NG Purchase date...

Page 29: ...7 for information EQUIPMENT SHUTOFF VALVE RMH 120 00088 For all models Equipment shutoff valve with 1 8 NPT tap SERVICE HINTS When Gas Pressure Is Too Low pilot will not stay lit burners will have del...

Page 30: ...ge resulting from any of the following Negligent use or misuse of the product including exposing the product to chemicals or cleaning products not approved by SHM International Corp Corrosion rust or...

Page 31: ...I PERCIBE OLOR A GAS No intente encender ning n aparato No toque ning n interruptor el ctrico no use ning n tel fono en el edificio Llame inmediatamente a su proveedor de gas desde el tel fono de alg...

Page 32: ...deben tomar las medidas necesarias para asegurar que haya suficiente aire para ventilaci n y combusti n Consulte la secci n Aire para combusti n y ventilaci n en la p gina 38 de este manual ADVERTENC...

Page 33: ...a los de la gripe con dolores de cabeza mareos y o n usea Si usted presenta estos s ntomas es posible que el calentador no est funcio nando correctamente Respire aire fresco inmediatamente Haga que le...

Page 34: ...e apaga no lo vuelva a encender hasta que se le haya pro porcionado aire fresco del exterior Si el calentador continua apagando se debera ser revisado por personal calificado 6 No haga funcionar el ca...

Page 35: ...IDO Este calentador est equipado con un en cendedor piezoel ctrico este sistema no requiere de f sforos bater as u otras fuentes a encender el calentador 2 OPCIONES DE GAS DISPONIBLES El calentador es...

Page 36: ...licencia para ejercer en el es tado de Massachusetts Los vendedores de calentadores com plementarios de interiores a base de gas propano o de gas natural y sin ventilaci n deben proporcionar a cada c...

Page 37: ...calentadores de habitaci n sin ventilaci n son recomendables como calefacci n suplementaria una habitaci n m s que como fuente principal de calefac ci n una casa entera En la mayor a de las aplicacio...

Page 38: ...necesita respirar El airefrescodebeentrarasucasa Todoslosapara tosquequemancombustiblenecesitanairefresco para la combusti n y la ventilaci n adecuada Los extractores de aire chimeneas se cadoras de r...

Page 39: ...ura 2 Tam bi n se puede quitar la puerta de la habitaci n adyacente consulte la opci n 3 figura 2 Con sulte el C digo Nacional de Gas Combustible ANSI Z223 1 NFPA 54 Aire para Combusti n y Ventilaci n...

Page 40: ...RECAUCI N Este calen tador crea corrientes de aire caliente Estas corrientes mue ven el calor hacia la superficie de las paredes pr ximas al calentador La instalaci n del calentadorcercadeparedescon r...

Page 41: ...l acceso para la ope raci n inspecci n y servicio 2 En la parte m s fr a de la habitaci n Al instalar el aparato directamente sobre al fombras baldosas u otro material combustible que no sea el suelo...

Page 42: ...etire el soporte de montaje del panel posterior M todos para fijar el soporte de montaje a la pared Use nicamente el ltimo orificio de cada extremo del soporte de montaje para fijarlo a la pared Fije...

Page 43: ...ORTANTE no golpee la llave con un martillo Para paredes gruesas de m s de 1 3 cm 1 2 de ancho o paredes s lidas no abra las alas 5 Coloque el soporte de montaje en la pared Alinee el ltimo orificio de...

Page 44: ...tornillo en la abertura del anclaje de pared o del orificio que perfor 8 Apriete los tornillos hasta que el calentador est asegurado firmemente a la pared No los apriete demasiado Nota No vuelva a col...

Page 45: ...exi n deentradayapretada este mbo lo se ech hacia atr s mediante la instalaci n de hacer todos los ajustes para el gas que se sumi nistra NO QUITE EL MBOLO El regulador no funcionar El regulador de en...

Page 46: ...iona gire hacia la derecha el ajuste hasta que las roscas se acoplan al regu lador Despu s de la instalaci n se ha apretado sido parte en el regulador con una llave para completar endurecimiento del a...

Page 47: ...alenta dordirectamentealsuministrode gas propano LP Este calentador requiereunreguladorexterno no se incluye Instale el regulador externo entre el calentador y el suministro de gas propano LP El prove...

Page 48: ...el equipo la uni n y el tap n con rosca NPT de 1 8 Sit e el conector con rosca NPT a su alcance para realizar la conexi n del medidor de prueba El conector tipo NPT se debe conectar en direcci n del s...

Page 49: ...tema de tuber a de suministro de gas Aplique en todas las uniones alg n l quido de detec ci n de fugas que no sea corrosivo La formaci n de burbujas indicar una fuga 5 Repare todas las fugas inmediata...

Page 50: ...arla llame a un t cnico de servicio capacitado Forzarla o tratar de repararla pueden producir un incendio o una explosi n D No use este aparato si alguna de sus partes estuvo sumergida en agua Llame i...

Page 51: ...o la perilla de control y al mismo tiempo oprima y suelte el bot n de encendido Esto encender el piloto El piloto est instalado en la parte anterior del quemador El piloto puede ser visto a trav s de...

Page 52: ...tenga el f sforo en el piloto hasta que ste se encienda PRECAUCI N no intente ajustar los niveles de calefac ci n por medio de la v lvula de cierre del equipo ADVERTENCIA Si el tipo de entradadegasesN...

Page 53: ...de limpieza o servicio de mantenimiento consulte Cuidado y mantenimiento p gina 54 ADVERTENCIA S lo una persona de servicio capacitada debe repararlo o darle servicio Esto incluye el mantenimiento re...

Page 54: ...ILOTO azul Algunos orificios del quemador pueden bloquearse con desechos u xido y no hay llama Si es as apague el calentador y d jelo enfriar luego elimine el bloqueo o remplace el quemador Si los ori...

Page 55: ...consulte la figura 26 Con la unidad apagada haga pasar aire ligeramente a trav s del orificio de entrada de aire Si no cuenta con aire comprimido puede soplar a trav s de una pajilla o popote Figura 2...

Page 56: ...Esto pasar por alto la funci n de interruptor de presi n SOLUCI N DE PROBLEMAS ADVERTENCIA Si percibe olor a gas Cierre el suministro de gas No intente encender ning n aparato No toque ning n interru...

Page 57: ...el bot n de encendido 3 Qued aire en las l neas de gas nueva instalaci n o interrupci n gas reciente 4 El piloto ODS est tapado 5 La presi n de gas es inade cuada o el regulador de en trada de gas es...

Page 58: ...el equipo totalmente 4 Apriete con la mano hasta que sienta que topa luego apriete 1 4 de vuelta m s 5 A Comun quese con la com pa a local de gas natural o de gas propano LP B Limpie el piloto ODS con...

Page 59: ...illa de control a la posici n alto cuando el quemador estaba fr o 2 Hay aire en la tuber a de gas 3 Los pasajes de aire del ca lentador est n bloqueados 4 El orificio del quemador est sucio o parcialm...

Page 60: ...a 3 El piloto ODS est parcial mente tapado 1 Abra la ventana y o la puerta para proporcionar ventilaci n 2 Contacte a su proveedor local de gas 3 Limpie el piloto ODS consulte Cuidado y mantenimiento...

Page 61: ...cio al cliente al 1 800 229 5647 para solicitar piezas que no est n bajo garant a Cuando llame a Servicio al Cliente tenga preparados los n meros de modelo y de serie de su calentador el n mero de la...

Page 62: ...www sureheat com 200311 01C 62 PIEZAS MODELO BWH10NLMC 2 2 11 3 17 9 8 7 1 16 10 5 6 14 13 15 4 12...

Page 63: ...rico 1 4 161392 01 Conjunto de v lvula de termostato 1 5 Conjunto de quemador 1 6 161139 02 Piloto ODS 1 7 Regulador de seguridad de combustible dual 1 8 161200 01 Entrada cubierta del enchufe 1 9 160...

Page 64: ...tancias qu micas o productos de limpieza no aprobados por SHM International Corp Corrosi n oxidaci n o des coloraci n de cualquier tipo Uso o instalaci n contrarios a las instrucciones especificadas y...

Reviews: