SmokeSight SS10MANN V0.6
Page 2
Mounting Base – Top View
Mounting Base – Bottom View
4.
Locking Tab
5.
Tamper Clip
6.
Mains Lid
7.
Mains, Loop and
Interlink Terminals
2
Specifications
Application
Residential Smoke Alarm for domestic
dwellings
Environment
Altitude: 0m to 2,000m
Temperature: 0°C to 40°C
Humidity: 5% to 95%
Installation
Ceiling or wall mounted
Audible
Indication
Alarm: 85dBA at 3m, ISO 8201
Battery Low: Chirp
Primary
Power Supply
220/240VAC, 50Hz, 30mA
Visual Indication Mains Supply: Green LED
Alarm: Red LED
Terminals
4 Screw Terminals
Voltage Rating: 300VAC
Conductor Size: 2 × 1.5 mm2, min
cable size: 1mm2
Interlink
Wired: 40 alarms over 150 metres
maximum
Secondary
Power Supply
2 x 1.5VDC AA Batteries
Compliance
AS 3786:2014, AS/NZS 60065,
AS/NZS 60950.1, IEC 62599.2
Sensing Type
Photoelectric. The smoke alarm
contains NO radioactive material
3
Locations
This smoke alarm can be used in all residential homes and apartments and positioned in accordance with building
regulations and state legislation. Refer to figure below when deciding the number of and location of smoke alarms.
Avoid dead air space positions. Install smoke alarms along exit paths from bedrooms. Locate alarms in stairways as
stairways act as chimneys for smoke and heat. Locate a smoke alarm in any area where a smoker sleeps or where
electrical appliances are used in bedrooms. Smoke, heat and other combustion materials rise to the ceiling and
spread horizontally. In a residential dwelling, mount the smoke alarm in the centre of the ceiling. In mobile homes,
wall mount the smoke alarm on an inside partition to avoid the thermal barrier that may form under the ceiling.