SmokeSight Residential Smoke Alarm 

By Redbusbar 

 
Part Number:  SS10MAMA 
Description: 

240 VAC Mains Power Photoelectric Smoke Alarm with Option Card & 4xAA 1.5VDC Battery Backup 

 

PLEASE LEAVE THESE INSTRUCTIONS WITH THE OCCUPANT, TO BE RETAINED FOR THE LIFE OF THE ALARM. 

THIS SMOKE ALARM MUST BE INSTALLED BY A LICENSED ELECTRICIAN. 

Read all Instructions before Installation and Operation 

Regular testing of this smoke alarm is necessary to ensure the unit is functional and that the battery is in good 
condition. It is recommended that the smoke alarm be replaced after 10 years of normal service. The only user-
serviceable parts are the replaceable backup batteries. Refer to ‘Replacing the Backup Batteries’.  
 

 

 

 

RISK OF ELECTRIC SHOCK, EXPLOSION OR ARC FLASH 
• This product must only be installed and serviced by 
appropriately qualified and/or licenced electrical 
personnel. 
• This product must only be used for the purpose 
described in these instructions and must be installed in 
accordance with the local regulations. 
• Hazardous voltages may be present at wires 
connected to this product. 
• Before working on this product, isolate the electrical 
supply. 
• Ensure that the product has been correctly installed 
and tested for safe operation before reconnecting the 
electrical supply. 

Failure to comply with these instructions may result in 
death or serious injury. 

 

EQUIPMENT INSTALLATION HAZARD 
• This alarm cannot be operated from power derived 
from a square wave, modified square wave or modified 
sine wave inverter. These inverters are sometimes 
used in off grid installations such as solar or wind 
power sources. They produce high peak voltages that 
will damage the alarm. 
• Ensure that the mains supply, active and neutral is 
wired to the correct terminals. 
• Ensure that green LED is ON when mains supply is on. 
• Ensure that red LED is not fast flashing. 
• Smoke Test each interlinked alarm. Check to ensure 
every interlinked alarm, alarms correctly. If any unit 
fails to alarm, check all wiring and connections. 

Failure to follow these instructions may result in 
equipment damage or injury. 

 

Smoke Alarm – Top View 

 

Smoke Alarm – Bottom View 

 

1.

 

Mains (Green) LED 

2.

 

Alarm (Red) LED 

3.

 

Option Card (White) 
LED 

4.

 

Smoke Alarm Battery 
Holder 

5.

 

Option Card Battery 
Holder 

6.

 

Option Card 
Configuration 
Switches 

 

 

 

 

Summary of Contents for SmokeSight SS10MAMA

Page 1: ...tages may be present at wires connected to this product Before working on this product isolate the electrical supply Ensure that the product has been correctly installed and tested for safe operation...

Page 2: ...The smoke alarm contains NO radioactive material Environment Altitude 0m to 2 000m Temperature 0 C to 40 C Humidity 5 to 95 Audible Indication Alarm 85dBA at 3m ISO 8201 Battery Low Chirp Visual Indic...

Page 3: ...r the ceiling Alarm Locations to Avoid Within 1 metre of air conditioner ducts ceiling fans and other high air flow areas Smoke may be blown away or diffused in these areas In areas where the temperat...

Page 4: ...ncorporates radio interlinking functionality As such it can operate as a gateway device to connect wired and wireless interlinked alarms Refer to Installation for the interlink connection arrangement...

Page 5: ...e mounting base unless the smoke alarm batteries are installed as damage may result Ready to slide Engages with a click Slide 11 Turn on the mains power and check that the green red and white LEDs fun...

Page 6: ...iguration command success is reported by one long flash beep while command failure is reported by two long flashes beeps The current configuration mode menu is reported every 10secs if no command is r...

Page 7: ...eeps 0 Add Radio Node Build Radio Network Mode Active 5flash 5beep every 10sec 4 Return to Operation Mode Auto Test Configuration Mode Command Taps Description Response White LED Flashes Beeps 0 Radio...

Page 8: ...Interlink Loss Master or Network Lost After 10mins 4 White LED Flashes Beeps Auto Test Fail Replace the smoke alarm Alternatively press the Test Hush button and if the smoke alarm sounds disable Auto...

Page 9: ...s on each smoke alarm eg the smoke alarms are mounted on a high ceiling Return to Factory Defaults would allow the Initial Setup procedure to be repeated It is assumed that the Radio Interlink switch...

Page 10: ...d the network as a slave 4 Once all alarms have been configured they will all be placed into Operation Mode 2mins after the last alarm has joined the network as a slave or by 4Tap of any node s Test H...

Page 11: ...plied with power Continue with the following steps only if you wish to change Auto Test times 2 Select Auto Test Configuration Mode From Operation Mode this can be achieved by 4Tap 2Tap of the Test Hu...

Page 12: ...LED is illuminated when the mains power is applied When the Alarm Sounds 1 Alert small children in the home 2 Leave immediately by your plan of escape Don t waste time getting dressed or picking up va...

Page 13: ...during this period from a smoke or fire event the unit will go into alarm mode Before using the alarm HUSH feature identify the source of smoke and be certain that a safe condition exists Replacing th...

Page 14: ...operation While the Test Hush button is pressed the alarm does not sound The smoke alarm may not be operating correctly Check that the green LED is ON and the red LED flashes once every 5mins If probl...

Page 15: ...has accumulated ALWAYS TEST THE SMOKE ALARM AFTER CLEANING If the smoke alarm is defective in any way do not tamper with the smoke alarm The smoke alarm does not contain any user serviceable parts As...

Page 16: ...SmokeSight SS10MAMA V0 5 Page 16 This page is intentionally left blank...