The A 4585 is a 16 zone paging system which switches 100V speaker levels or balanced low level (line levels) signals.
Background music which can be piped to any zone is muted when paging is initiated by the A 4586 paging consoles or
when the Evac input is triggered.
WARNING : For correct operation the dip switches 1 & 2 need to be set before using the unit.
If the A 4585 is being used in single amplifier mode (see section 2.2.1) dip switch 1 must be set to “ON”
otherwise if the unit is being used in two amplifer mode (see section 2.2.2) then dip switch 1 must be set to “OFF”
When using the unit for 100V speaker switching Dip switch 2 must be set to “OFF”.
If line level switching is required then Dip Switch 2 must be set to “ON”.
Failure to set the dip switches correctly might result in the unit malfunctioning.
Fig 1.6A
12
Dip Switch Settings
Fig 1.6A shows the settings available.
DIP switch 1
sets the amplifier mode, either single amp or dual amp mode. (see section 2.2 for more details)
DIP switch 2
sets the output level, either line level or 100V speaker level. (see section 2.2 for more details)
DIP switch 3
sets the 24V DC switched output configuration. This can be set to operate when any zone is
triggered or for Evac triggering (see section 2.5 for more details).
DIP switches 4-8
are not used.
.
Note: The DIP switches are ON when they are down.
DIP Switch Settings
SW
1
2
3
On
Off
Single Amp Mode
24V DC Output
EVAC trigger only
Dual Amp Mode
Line Level
Speaker Level
4-8
24V DC Output
any zone trigger
NOT USED
13
From BGM AMP input
Connect this 100V line input from the 100V output of the BGM (background music) amplifier.
14
From PA AMP input
Connect this 100V line input from the 100V output of the PA (or paging) amplifier.
15
Zone 1-16 outputs.
The zone outputs can be either 100V or line level depending on configuration of the dip switches (see Fig1.6A)