3.1 SYMPTOMS AND REMEDIES 

SYMPTOMS

REMEDIES 

Check that the 100KΩ EOL resistor is 

fitted to the end of the line and that 

22uF BP capacitors are fitted to all 

speakers. If they are fitted there must 

be a short across the line.

The “SHORT” LED comes up on a zone.

No power to unit.

Check fuse and replace with M205 type 1A 

fuse if required. 

Specifications

OUTPUT CONNECTORS:
 

Open 24V DC Out:......................... Screw Terminals

 

Short 24V DC Out:..........................Screw Terminals

 

Combined 24V DC Out:...................Screw Terminals

INPUT CONNECTORS:
 

 

24V DC Power:.....................Screw Terminals

 

 

Zone connections:.................Screw Terminals

CONTROLS:
 

Cancel Switch:.......................................Push Switch

INDICATORS:.......................Power on, Zone fault condition

POWER SUPPLY:.................................................... 24V DC

DIMENSIONS:≈................................... 483W x 177D x 44H
WEIGHT: ≈............................................................... 3.7 kg
COLOUR: ..................................................................Black

* Specifications subject to change without notice

Check that the 100KΩ EOL resistor is 

fitted to the end of the line and that 

22uF BP capacitors are fitted to all 

speakers. If they are fitted there must 

be a break in the line.

The “OPEN” LED comes up on a zone.

4.1 SPECIFICATIONS

Summary of Contents for A 4567B

Page 1: ...1300 780 999 Fax 1300 790 999 Internet www altronics com au IMPORTANT NOTE Please read these instructions carefully from front to back prior to installation They include important setup instructions F...

Page 2: ...ur LED indicates line condition accordingly for each zone Internal audible alarm buzzer with cancel button is fitted With any fault condition a switched output is provided for remote monitoring purpos...

Page 3: ...Red indicates a Short condition i e there is a short circuit on the line 3 Buzzer The buzzer sounds when either an Open or a Short condition occurs on a zone 4 Cancel Buzzer Button This button is used...

Page 4: ...n the N O and ground terminals when this output is activated When this output is not active 24V appears between the N C and ground terminals 7 Short 24V Output This is a 24V DC output which is activat...

Page 5: ...the end of the lines and all speakers must have 22uF Bipolar caps fitted See Fig 2 2 for more details NOTE The maximum wire run is 200 metres An A 4568 Fire Indicator Board Interface has been connecte...

Page 6: ...peaker line going out of speaker termination Loop Out End of Line resistor 100K 0 25W Speaker line coming into speaker termination Loop In Fig 2 2b Fig 2 2c Fig 2 2d Fig 2 2a shows an Altronics C 2168...

Page 7: ...or Short condition on any zone The terminals provided can be used for Normal or Failsafe modes The output terminals have a N O normally open N C normally closed and a ground connection In this configu...

Page 8: ...NECTORS Open 24V DC Out Screw Terminals Short 24V DC Out Screw Terminals Combined 24V DC Out Screw Terminals INPUT CONNECTORS 24V DC Power Screw Terminals Zone connections Screw Terminals CONTROLS Can...

Reviews: