Redback A 4506 Operating Manual Download Page 1

Operating Manual

A 4506  

 

6A Battery Charger

A 4512 

12A Battery Charger

The A 4506 and A 4512 battery chargers are ideally suited for PA systems requiring battery back up in the event of mains 
power failure. 

The design incorporates a highly efficient, intelligent, multi stage switchmode battery charger ensuring optimum battery 
charging and performance.
This charger has been specifically designed for use on sealed lead acid batteries (SLA).

1.0 Features

• Short circuit protection 
• Electronic reverse polarity protection 
• 2 stage charging 
• 2 switched 50 amp outputs
• Automatic boost and float voltages 
• Precision control of boost and float voltage settings 
• Battery Isolator/circuit breaker
• 24V DC Auxiliary outputs (maximum load 1 amp)
• Digital battery voltage display 
• Digital battery current display
• Charging mode status indicators 
• Mains/battery/low battery status indicators
• 24V out status indicator
• Low voltage cut off to protect battery 
• 2U 19” rack mount chassis 
• 2 year warranty 
• Ideal for sealed lead acid batteries 
• Australian designed and manufactured 
• Made in Australia

User manual revision number 1.0 26/02/2016

Summary of Contents for A 4506

Page 1: ...ort circuit protection Electronic reverse polarity protection 2 stage charging 2 switched 50 amp outputs Automatic boost and float voltages Precision control of boost and float voltage settings Batter...

Page 2: ...ult condition Boost charge mode Solid orange LED Absorb charge mode Flashing orange LED Trickle charge mode Solid green LED Fault Mode Solid red LED 4 Auxiliary 24V Out Indicator This LED indicates wh...

Page 3: ...he load s A maximum load of 50 amps per set of load terminals 8 Battery Isolate Reset This breaker can be used as an isolator to quickly disengage the batteries without having to disconnect leads It a...

Page 4: ...nnect in parallel overnight 10 12 hours minimum prior to connecting them to the charger Failure to do this can cause a severe inbalance in the charging of the batteries causing permanent damage 12V Ba...

Page 5: ...d load 1 ve and if required to load 2 ve and load 2 ve Note the load current is limited to 50 amps maximum per load Model A 4506 A4512 AC Fuse M205 5A 5A RISK OF ELECTRIC SHOCK OPEN BY QUALIFIED PERSO...

Page 6: ...ur Should mains power fail the unit will automatically switch the connected load s to the battery When mains power is restored the load s will be disconnected from the battery LED s on the front panel...

Page 7: ...y voltage Check that you have connected a lead from the battery to the terminals labelled Battery Voltage Unit will not charge battery Check connections to To battery terminals and to the battery Make...

Page 8: ...isplay Battery Voltage 3 5 Digit LCD Battery Current 3 5 Digit LCD Trickle charge Green LED Float charge Flashing Yellow LED Boost Charge Yellow LED Mains Power Green LED Battery Power Yellow LED Low...

Reviews: