11
6
SYSTEM WIRING
7.3 BCDC Solar Blanket Connection with RK1260
Loads
Load
Fuse
Fuse
Battery
config.
wire
Start
Battery
Fuse
RK1260
to vehicle
ignition
Note: Power wires must be
at least 6 mm² (9 AWG) and must be
crimped using an
appropriate crimp tool.
All ground points must
be connected to chassis
earth.
Auxiliary
Battery
30
87
87a
85
86
Blue
Red
Black
Purple
10 m (32.9') SRC0019 or
1.5 m (4.1') SRC0008 or
5 m (16'5") SRC0018
BCDC1225,
or
BCDC1250
+
+
BCDC1240
7.4 BCDC Solar Blanket Connection
10 m (32'9") SRC0019 or
1.5 m (4'11") SRC0008 or
5 m (16'5") SRC0018
Anderson
Connector
(not included)
BCDC1225D,
or
BCDC1250D
+
+
BCDC1240D
12V or 24V
Start Battery
Bank
Fuse
Fuse
Optional LED
All ground points must
be connected to chassis
earth.
Auxiliary
Battery
Charging Profile Select
Refer to BCDC manual
Red
Blue
Orange
Black
Bro
wn
Green
Yello
w
Standard
Trigger Settings
Low Voltage
Trigger Settings
Load
Fuse
Loads
to Vehicle Ignition
Refer to BCDC manual
Leave unconnected
Refer to BCDC manual