2 OPERATION
2.1
The Display Panel
The Display Panel features 3 Charging Status LEDs, 3 Battery type indication LEDs and 1
Selector Button as outlined above.
• Charging
ORANGE
LED
• Ready
GREEN
LED
• Fault
RED LED
• Standard Lead Acid
YELLOW LED
• Calcium content Lead Acid
BLUE LED
• Gel/AGM (Default)
GREEN LED
2.2 Selecting
Battery
Type
You will have 60 seconds from the moment the charger is turned on to make the selection.
During the selection period, the selected battery type LED will fl ash. Once 60 seconds
has expired, the selection is locked in for the remainder of the charging period and
the selected battery type LED will remain permanently illuminated. Should an incorrect
battery be selected, the battery charger should be turned off for approximately 10
seconds, then turned back on. The correct battery selection can now be made.
2.3
The Charging Process
The SBC has been designed to return a discharged battery to 100% charge through a
rigorous charging cycle. This charging cycle assumes that no load is connected to the
battery during charging, otherwise full charge may not be achieved. It is also possible
that the charger may determine that the charging characteristics with a load applied
4