Specifications
Part Number
BCDC1220
BCDC1220-IGN
Continuous Current Rating
20A
Input Fuse Rating
40A (Not Supplied)
REDARC FK40 recommended
Output Fuse Rating
Output Power
300W
DC Input Voltage Range
*1
9-32V
9-32V
Output Battery Type
Standard Lead Acid, Calcium content, Gel & AGM type only
Charging Profile
A
B
C
-
Maximum
Voltage
*1
(refer to section 2.3)
14.6
15.0
15.4
-
Float
Voltage
*1
13.3V
No Load Current
<100mA
Standby Current
<5mA
Ambient Temperature
-20°C to +80°C
Minimum O/P Battery Volts
*1
4.0V
Weight
450g
Dimensions
100x120x37mm
Warranty
2 years
Standards
CE, C-Tick, AS/NZS CISPR11:2004
*1
Voltages Specified are ±100mV