background image

 

Hush or Silence Feature

• This smoke alarm has a built-in Hush or Silence feature incorporated into 

the Test/Hush button. 

• If cooking or other non-hazardous sources cause the alarm to sound, it can 

be temporarily silenced by pressing the Test/Hush button for 3 seconds. 

• The alarm then enters a dormant period for 10 minutes. The red LED will 

flash every 10 seconds to indicate the sensitivity is reduced. 

• After the 10 minute dormant period, the alarm will give two short beeps, and 

the alarm will resume normal operation.

NOTE: 

After the Test/Hush button has been pressed, wait 10 minutes before 

any additional testing is conducted to avoid any abnormal responses as the 

smoke alarm is not sensitive to smoke during this period.

NOTE: 

If a nuisance alarm occurs and if there is no sign of smoke, heat or 

noise to suggest a fire you should get your family to a safe place before 

investigating. Check the household carefully in case there is a small fire 

smouldering out of sight, or if there is another source of smoke or fumes such 

as cooking fumes being drawn past a smoke alarm by an extractor. 

WARNING: 

If there are frequent nuisance alarms it may be necessary to 

re-locate the device away from the source of the fumes. If the alarm continues 

sounding nuisance alarms without smoke or heat being present; It may 

require some maintenance or cleaning

THIS PRODUCT IS A SEALED UNIT AND CANNOT BE REPAIRED – 

IF THE UNIT IS TAMPERED WITH IT WILL INVALIDATE THE 

WARRANTY. IF THE UNIT IS FAULTY PLEASE RETURN IT TO 

YOUR ORIGINAL SUPPLIER WITH YOUR PROOF OF PURCHASE.

Maintenance:

The smoke alarm is virtually maintenance free. However, under dusty or greasy 

conditions, a vacuum cleaner may be used to clean the exterior of unit (including 

slots on cover). Normally, the alarm can be operated up to 10 years without 

replacement. See the replacing date on the bottom of the alarm unit. 

DO NOT IMMERSE IN OR SPRAY WITH HOUSEHOLD CLEANERS. 

If the unit gives a chirping sound every 60sec the battery may need to be replaced.

Battery:

Battery replacement is not required and the battery cannot be removed.
Low Battery

If the smoke detector emits a short ‘beep’ once every 40 seconds the battery is at 

the end of its life and this detector should be replaced immediately. This low 

voltage warning will be given for at least 30 days.

If the red indicator light (LED) does not flash every 40 seconds then replace the 

whole smoke alarm unit.

OPERATION, TESTING AND MAINTENANCE

Operation

Normal Operation When no smoke is present, a red LED indicator will flash ONCE A 

MINUTE and is an indication that the unit is operating properly. 

The hush feature can mute the detector if it has been inadvertently triggered by 

holding down the test/hush button for a few seconds. The smoke alarm will be muted 

for 10 minutes and then reset into normal mode after this period.

NOTE: If the smoke density increases during the hush period the smoke alarm will be 

triggered into sounding again.

Alarm Condition

When the unit detects smoke, the red LED indicator will flash rapidly and alarm will 

sound loudly until the air is clear.

Testing the Smoke Alarm 

Test the smoke alarm once a week. If the smoke alarm ever fails to test correctly, 

have it replaced immediately! If the smoke alarm is not working properly, it cannot 

alert you to a problem.

1. Test each smoke alarm to be sure it is installed correctly and operating properly.

2. The push-to-test button accurately tests functions. DO NOT use an open flame to 

test this smoke alarm. You may ignite and damage the smoke alarm or your home.

3. Stand at arm’s length from the smoke alarm when testing.

4. To test the smoke alarm firmly press the test button, and the alarm will sound a 

loud beep. The alarm will stop sounding after releasing the test button. If the alarm 

does not sound please re-test the alarm.

WARNING: 

If the alarm sounds and the smoke alarm is not being tested, the smoke 

alarm is sensing smoke. The sound of the alarm requires your immediate attention 

and action.

Areas to be avoided include the following:

• Situations where the temperature may fall below 0 C or rise above 40 C 

• Humid areas such as bathrooms, kitchens, shower rooms where the 

relative humidity may exceed 90%

• Near a decorative object, door, light fitting, window molding etc., that may 

prevent smoke or heat from entering the alarm.

• Fume filled environments such as garages.  Exhaust gases may cause false 

alarms.

• Adjacent to or directly above hot components such as radiators or wall vents 

that can affect the direction of air currents.

• In very dusty or dirty environments such as workshops.

• Locate unit at least 1.5m and route wiring at least 1m away for fluorescent 

light fittings as electrical “noise” and/or flickering may affect the unit. Do not 

wire into the same circuit as fluorescent lights or dimmers.

• Do not locate in insect infested areas. Insects and contamination on the 

Heat Alarm sensor can increase its response time.

o

o

Warranty: 

The smoke alarm is warranted to be free from defects in materials and workmanship for five (5) years from the date of purchase and is not transferable under normal 

use. The warranty does not cover natural disasters such as fire, flood, hurricanes and tornados. Warranty is conditional on the smoke alarm being used in the normal 

way and not being modified or subject to attempted repairs or contamination. The warranty excludes the battery, incidental and consequential damages. Your statutory 

rights as a consumer are in no way compromised by this warranty. Red Smoke Alarms agrees to repair or replace, at its option, any defective smoke alarm provided it is 

returned personally or by prepaid delivery with a copy of proof of purchase. This warranty does not cover damages resulting from lack of reasonable care of the product. 

Our goods come with guarantees that cannot be excluded under the Australian Consumer Law. You are entitled to a replacement or refund for a major failure and for 

compensation for any other reasonably foreseeable loss or damage. You are also entitled to have the goods repaired or replaced if the goods fail to be of acceptable 

quality and the failure does not amount to a major failure. 

Subject to those non-excluded rights and provisions and the above warranty, Red Smoke Alarms will not be liable for injury to persons, damage to property, or for any 

direct or indirect or consequential damage as a result of negligence or fault on the part of Red Smoke Alarms or it’s servants, agents, suppliers and contractors or 

otherwise arising out of or resulting from, whether directly or indirectly, the use, installation or maintenance of the smoke alarm and any warranties or representations 

are excluded unless given by Red Smoke Alarms in writing. Please leave this document, or a copy, for the end user.

Red Smoke Alarms reserves the right to change specifications, 

modify designs and discontinue items without incurring obligation 

and whilst every effort is made to ensure that descriptions, specifica-

tions and other information in this catalogue are correct, no warranty 

is given in respect theseof and the company shall not be liable for any 

error therein.

© Red Smoke Alarms 2020

This material copyright under Australian and international laws. 

Except as permitted under the relevant law, no part of this work may 

be reproduced by any process without prior written permission of and 

acknowledgment to Red Smoke Alarms.

MNPRG86610YRF175A0

RED SMOKE ALARMS PTY. LTD.

P O Box 9596

PACIFIC PARADISE QLD 4564

[email protected].

www.redsmokealarms.com.au

1300 316 552

SMOKE ALARMS

Reviews: