![RED ROOSTER RRI-BIM15T Manual Download Page 6](http://html1.mh-extra.com/html/red-rooster/rri-bim15t/rri-bim15t_manual_1428349006.webp)
Do not use worn or bad fitting impact sockets or extensions, as this is likely to increase noise and vibration.
Make sure that the inserted/mounted tool/accessory is properly held by the retainer and make sure that the retainer is in good
condition. Never use the tool without a retainer as this may cause high speed projectiles.
Only use impact rated sockets when using impact or impulse wrenches.
Using the tool:
Before start using the tool, make sure that you are familiar with the workplace and surrounding area.
Always obey the safety regulations for the work area you are working in.
During operating the tool, the operator may be exposed to hazards as crushing, impacts, heat, vibration, cuts, abrasions, etc: Wear
suitable gloves.
Any person handling the tool must be able to handle the size, weight and power of the tool.
Always be prepared for normal/abnormal movements/forces generated by the tool.
Keep your body in balance, place your feet safe and secure.
Take care of the reaction forces, if the tool (suddenly) stalls.
When using a power tool, you may experience discomfort in your hands, arms, shoulders, neck and other parts of your body.
If you experience symptoms such as persistent or recurring discomfort, pain, throbbing, aching, tingling, numbness, burning sensation,
or stiffness: Do not ignore these warning signs. Stop using the tool, tell your employer and consult a qualified health professional.
Check if the direction of rotation is in the required direction.
Adjust the torque according the requirements for the application, see below paragraph: Adjustments.
Place the tool with the accessory on the bolt/nut screw.
Pull the trigger to start the tool and release the trigger to stop the tool.
Do not overtighten the bolt/nut/screw, a broken part can become a projectile causing danger or injury.
When loosening the bolt/nut/screw may become a projectile causing danger or injury.
Operator should change posture regularly to avoid discomfort and fatigue.
Use hear protection according to employer, health and safety regulations.
Torque adjustment
Remove the battery before adjusting.
Rotate the main shaft until the hole (2 mm) of the valve screw is in front a groove, for the RRI-BIM15T please remove the small screw.
Clockwise = increase torque output, counterclockwise = decrease torque output.
How to test the torque
Test method 1: Static measurement, either on a test joint or actual application. Measure the move on torque with a torque wrench.