Inside US: +1 (877) 432-9908
Quick Start Guide
Outside US: +1 (717) 767-6511
RAM® Series
www.redlion.net
Drawing No. LP1061-A
-1-
RAM® 6021M12 Router
Unpacking Instructions
1.
Unpack the Red Lion unit and verify the following components are enclosed in the package:
•
Quick Start Guide
•
RAM-6021M12 Router
2.
The RAM-6021M12 is powered by two redundant power inputs located on a single 5-pin
M12 A-coded connector.
•
The router requires a power source rated between 8 and 49 VDC
3.
Connect to the WAN or LAN port for network connectivity.
Item
Description
Input Voltage
Power 8 to 49 VDC
Steady Input Current
0.15A @ 24VDC
BTU/hr
12.25
Inrush Current
33.9A/0.0287ms @ 24VDC
Accessing the Web User Interface using AutoNet
1.
Connect the RAM-6021M12 router to an existing network.
a.
Connect an Ethernet cable between the router and your
local corporate LAN or directly to your PC/Laptop.
b.
Verify the green LED on the Ethernet port is lit.
2.
RAM-6021M12 will obtain its IP address via DHCP if a
DHCP server is present, if not the Ethernet interface will set
a static IP and enable a DHCP server on the interface. If
your PC is connected directly to the Red Lion router it will
obtain a local IP address from the router.
3.
Access Web User Interface
Open a web browser and navigate to http://ram-<Last 6 of
Ethernet MAC Address>:
Example:
http://ram-6d3f11.local/
Accessing the Web User Interface (Traditional Method)
1.
Connect the PC to the RAM-6021M12 router.
a.
Connect an Ethernet cable between the local PC and any
available Ethernet port.
2.
Setup PC IP Address.
PC to Ethernet Interfaces
Select “Use the following IP address” and fill in the blank
fields with the information below:
3.
Access Web User Interface
Open a web browser and enter the following in the address
bar:
•
WAN/ETH0:
http://192.168.0.1:10000/
•
LAN/ETH1:
http://192.168.1.1:10000/
Login Instructions
•
User Name:
admin (lowercase letters)
•
Password:
last six digits of the unit’s serial number
Upon successfully logging in, the web UI will launch.
Note:
For security purposes, it is recommended that the
admin password be changed according to your internal
policies.
To change password, go to:
Admin
Access Settings
.
If you have any problems getting connected, please refer to
the Red Lion Software Manual located at:
http://www.redlion.net
Web UI:
Item
WAN/ETH0
LAN/ETH1
IP Address
192.168.0.2
192.168.1.2
Subnet Mask
255.255.255.0
255.255.255.0
Default Gateway
192.168.0.1
192.168.1.1
Preferred DNS
192.168.0.1
192.168.1.1