MODEL

  

PAXLCL

 ‐ 

PAX

 

LITE

 

CURRENT

 

LOOP

 

METER

 

DUAL RANGE, 4 to 20 mA or 10 to 50 mA *

 3 1/2-DIGIT, 0.56" (14.2 mm) HIGH RED LED READOUT

24 VDC EXCITATION SUPPLY

WIDE SPAN & OFFSET SCALING RANGE

OVER-RANGE INDICATION

SELECTABLE DECIMAL POINTS

NEMA 4X/IP65 SEALED FRONT BEZEL

 OPTIONAL CUSTOM UNITS OVERLAY W/BACKLIGHT

* Also adapts to 0 to 50, 0 to 20, 0 to 10, 1 to 5 mA ranges as well as

bi-polar inputs.

GENERAL

 

DESCRIPTION

The features of the PAX Lite Series can be applied to measurement of

process variables. With its high sensitivity and programmability, the PAX
Lite Current Loop Meter can be set up for a wide variety of applications.
The PAXLCL can be used for most current loop meter needs for readout
of pressure, flow, temperature, level and other variables. The meter has
been specifically designed for harsh industrial environments. With NEMA
4X/IP65 sealed bezel and extensive testing of noise effects to CE
requirements, the meter provides a tough yet reliable application solution.
This allows the PAXLCL to be used in dirty, hostile environments and in
wash-down areas. The 3 1/2-digit bi-polar display (minus sign displayed
when current or voltage is negative) features 0.56" (14.2 mm) high, 7-
segment LEDs for easy reading.

SAFETY

 

SUMMARY

All safety related regulations, local codes and instructions that appear

in the literature or on equipment must be observed to ensure personal
safety and to prevent damage to either the instrument or equipment
connected to it. If equipment is used in a manner not specified by the
manufacturer, the protection provided by the equipment may be impaired. 

CAUTION: Risk Of Danger.

Read complete instructions prior to 

installation and operation of the unit.

CAUTION: 

Risk of electric shock.

DIMENSIONS

 

In

 

inches

 

(mm)

Note: Recommended minimum clearance (behind the panel) for mounting clip installation is 

2.1" (53.4) H x 5.0" (127) W.

1 2 3 4 5 6

7

8 9 10

3.60 (91.4)

(44.5)

1.75

(96.5)

3.80

1.95

(49.5)

(2.5)

.10

(104.1)

4.10

(44.5)

1.75

mA

C

US LISTED

UL

R

PROC. CONT. EQ.

E179259

Summary of Contents for PAXLCL Series

Page 1: ...s With NEMA 4X IP65 sealed bezel and extensive testing of noise effects to CE requirements the meter provides a tough yet reliable application solution This allows the PAXLCL to be used in dirty hosti...

Page 2: ...l display for a total offset range of 2700 8 LINEARITY 0 05 1 digit 9 READING RATE 2 5 updated readings second nominal 10 RESPONSE TIME 1 second to settle for step change 11 LOW FREQUENCY NOISE REJECT...

Page 3: ...t in place push the panel latch over the rear of the unit so that the tabs of the panel latch engage in the slots on the case The panel latch should be engaged in the farthest forward slot possible To...

Page 4: ...on network is normally installed across the load the contacts or both The most effective location is across the load a Using a snubber which is a resistor capacitor RC network or metal oxide varistor...

Page 5: ...nations to give 32 discrete steps of span The fine adjust control brackets these coarse steps and can be adjusted to the exact span needed The approximate span contributed by each switch is shown on t...

Page 6: ...in its case and apply power Apply zero current Adjust the indicator to read zero using the offset adjustment pot 5 Apply the SWING CURRENT Is 16 mA in this example to the input Set the exact READOUT...

Page 7: ...6 mA max rdg 15 mA min rdg 9 mA In this case the signal current is reversed Term 3 with respect to Term 5 causing the readout to go down increasingly negative as the negative current increases ADJUSTM...

Page 8: ...mer shall be responsible for determining that a Product is suitable for Customer s use and that such use complies with any applicable local state or federal law b The Company shall not be liable for a...

Reviews: