W
EB
S
OFTWARE
C
ONFIGURATION
R
EVISED
2018-09-21
Event Notification
D
RAWING
N
O
. LP0991-G
2-50
N-Tron
®
Series NT24K
®
Software Manual
2.16.2.1
Syslog
Configuration
View
The Syslog Configuration View is accessible under Event Notification within the Advanced section. Below is an
example of the current configuration status of Syslog, the configuration of each Syslog Collector, and a list of the
Syslog Collectors.
2.16.2.2
Syslog
Configuration
Modify
The Syslog configuration may be changed by an admin level user by clicking on the Modify button. In this section
the settings of each Syslog Collector can be updated and the Syslog Distributor itself can be disabled or enabled.
Syslog Status:
This field indicates whether the Syslog Distributor (client) has been enabled or disabled. To enable
Syslog at least one Syslog Collector (server) must be specified.
Facility:
This is used to identify which process is logging the message. This is a global setting for the switch and
will be used for all messages. Available Facility values as defined per RFC-5424 are 1 (user level) and 16 - 23
(local use).
Originator IP Address:
The field displays the configured IP address of the switch.
Collector:
The Syslog server to which the messages are sent.
IP Address:
The IP address of the Collector (server) to receive a log message.
UDP Port Number:
The UDP port on the Collector (server) to receive the message. The default port number is
514, per RFC-5424, but can be changed to meet installation requirements. Allowed port numbers are 1 - 65535.